Pressure test and gas tightness test for small air separation unit

Pressure test and gas tightness test for small air separation unit
Dec 10, 2025
Author: DEAR AST

1.1 The water used for the pressure test shall be clean domestic water ,for containers with complex structures or distillation towers, plate fin heat exchangers, condensing evaporators, adsorbers, filters, etc., which should not be used as a medium, the air pressure test is available.

1.2 Gas tightness test for dry oil-free clean air or nitrogen.

Test pressure categories: strength air pressure test, test water pressure test, gas tightness test

Pressure vessel

3.1 Level pressure gauge test nitrogen seal pressure.

3.2 multi-channel vessel test sealing nitrogen in doubt or no sealing nitrogen must be pressure test to verify whether there is internal leakage.

3.3 Oxygen is strictly forbidden to be used as test pressure gas

Valve

4.1 Where the need for on-site degreasing, disassembly and inspection of the valve before installation shall be a separate gas tightness test.

4.2 The safety is only tested by jumping. After reaching the requirements can be sealed, where the safety valve before the shut-off valve ,the valve must be kept fully open and sealed.

4.3 Pneumatic film control valves need to make the following checks before installation: leakage check, positioner action test,packing letter, flange sealing surface for leakage inspection.

Dear Air Separation manufactures small air separation unit that meets customer requirements and is pressure tested and gas tight tested.

山东传洋集团20000

DEAR Air Separation Solve YourPressure test and gas tightness test for small air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
If the temperature after the expander of the air separation unit is too low, it should find out the cause of the low temperature and take measures to increase the temperature after the expander. If the low temperature of expander is caused by liquid air in front of expander, appropriate measures should be taken to reduce the liquid air level of lower column. If it is caused by other reasons, the more effective method is generally throttling in front of the expander. Throttling will not increase the temperature in front of the expander, but throttling will reduce the pressure in front of the expander, so the pressure difference between the front and the back of the expander will be reduced, the expander will do less work and the temperature will be reduced, so the temperature at the after of the expander can be increased.
2026.06.01
What is the principle of return slop nitrogen removing frozen water and carbon dioxide?
2026.05.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top