Auxiliary condensing evaporator in liquid air separation plant is the device to remove acetylene and hydrocarbons from the condensing evaporator. In the condensing evaporator, liquid oxygen is continuously evaporated, while acetylene and other hydrocarbons contained in liquid oxygen are continuously concentrated. A part of the liquid oxygen is led from the bottom of the main cold evaporator, this part of the liquid oxygen evaporates in the auxiliary condensing evaporator and the acetylene and other explosive substances are concentrated in the auxiliary condensing evaporator before being led to the acetylene separator for regular removal.

Dear Air Separationsmall air separation unit, large air separtion plant and liquid air separation plant service team can give a reply to technical enquiries within 30 minutes; provide programme design direction within 24 hours; and provide feedback on complaint solutions within 12-24 hours.

亚洲硅业(青海)有限公司-3000

DEAR Air Separation Solve YourApplication of auxiliary condensing evaporator in liquid air separation plantYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process. Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area. The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g). Deere air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the w
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top