当前位置: Home / Faq / Liquefied air separation FAQ /

Application of auxiliary condensing evaporator in liquid air separation plant

Application of auxiliary condensing evaporator in liquid air separation plant
Apr 11, 2025
Author: DEAR AST

Auxiliary condensing evaporator in liquid air separation plant is the device to remove acetylene and hydrocarbons from the condensing evaporator. In the condensing evaporator, liquid oxygen is continuously evaporated, while acetylene and other hydrocarbons contained in liquid oxygen are continuously concentrated. A part of the liquid oxygen is led from the bottom of the main cold evaporator, this part of the liquid oxygen evaporates in the auxiliary condensing evaporator and the acetylene and other explosive substances are concentrated in the auxiliary condensing evaporator before being led to the acetylene separator for regular removal.

Dear Air Separationsmall air separation unit, large air separtion plant and liquid air separation plant service team can give a reply to technical enquiries within 30 minutes; provide programme design direction within 24 hours; and provide feedback on complaint solutions within 12-24 hours.

亚洲硅业(青海)有限公司-3000

DEAR Air Separation Solve YourApplication of auxiliary condensing evaporator in liquid air separation plantYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The load adjustment range of low pressure small air separation unit is related to the adjustment performance of the raw material compressor, the adjustment performance of the expander, the structural characteristics of the distillation tower and other factors. At present there are imported guide vane of the turbine air compressor flow adjustment range in 75-100%; adjustable nozzle of the turbine expander adjustment range can be in 65-100%. When oxygen is rich and the need to reduce oxygen produc...
2026.09.24
Causes of low air compressor efficiency of small air separation unit   There are many reasons for the low efficiency of air compressors, the common ones are: increase in suction temperature at any level, cooler leakage, decrease in grid frequency or voltage, blockage or increase in resistance of the compressor intercooler, gas leakage due to poor sealing, blockage or increase in resistance of the air filter, blockage or increase in resistance of the pipeline of the air separation equipmen...
2026.09.23
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top