How to clean vessels, valves and piping of large air separation plant?

How to clean vessels, valves and piping of large air separation plant?
Jan 07, 2022
Author: DEAR AST

All pressure vessels, valves and piping of small air separation unit and large air separation plant as well as the vicinity of the piping (in contact with oxygen or cryogenic media) must be clean, dry and free from oil and grease before installation. air separation unit which has been degreased by the manufacturer and is not contaminated can be installed without degreasing; if it is contaminated with grease, it should be degreased.

materials such as aluminium and magnesium, requirements: pH ≤ 10 for aluminium and magnesium parts, cleaning temperature 70 a 80°C. After cleaning with alkali solution, the parts should be rinsed with clean water until there is no residual alkali, and then dried.

Before installation and useage, oxygen piping should be blown clean of residues in the piping with oil-free dry air or nitrogen until it is free of rust, dust and other dirt. Blowing speed should be greater than 20m/s. Where the surface of the parts in contact with oxygen and the surface of the parts in operation where the residual oil may be carried to oxygen, the residual oil of the grease shall not exceed 125mg/m2, it is strictly forbidden to blow the pipeline with oxygen.

01

DEAR Air Separation Solve YourHow to clean vessels, valves and piping of large air separation plant?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The molecular sieve used in oxygen generators is the zeolite molecular sieve. It is a crystalline silica and aluminate polyhydric compound. Molecular sieves have a uniform pore size and their main function is to sieve molecules. There are three main types of molecular sieves: A, X and Y. The 13X molecular sieve is the only adsorbent currently used in liquid air separation plants. Any molecules that can be adsorbed on 3A, 4A and 5A molecular sieves can be adsorbed by 13X molecular sieves. It is c...
2026.09.30
Pressure test before valve installation 1. In the warranty period, those with the certification and the sealing surface is intact can no longer conduct the strength test alone, but only the air tightness test can be taken before installation. 2. Within the warranty period, it has the certificate, and its sealing surface has defects such as corrosion and damage. After treatment, it must carry out the air tightness test. 3. Outside the warranty period, those with certification and intact sealing surface shall be subject to air tightness test before installation. 4. For valves that need to be degreased and disassembled on site, air tightness test shall be conducted separately before installation. 5. The safety valve shall be sent to the local quality inspection department of the project for verification before the end of installation and commissioning.
2026.09.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top