What are the requirements for strength and airtightness tests before the small air separation unit is put in place?  

What are the requirements for strength and airtightness tests before the small air separation unit is put in place?  
Feb 14, 2025
Author: DEAR AST

Small air separation unit in place before the strength test and gas-tightness test provisions.

 

First, if the manufacturer has made strength test and has a certificate of conformity of the pressurized equipment, it may not be strength test only gas tightness test, but if the small air separation unit is found to have traces of damage or a site has been partially modified or parked for too long, the strength test should be made.

 

Second, the strength test should be applied to the water pressure method, the application of pneumatic pressure to equipment where water is not suitable as a medium or where the structure is complex. (distillation tower, plate fin heat exchanger, adsorption filter, etc.), the pneumatic test process must have reliable safety measures and can be carried out after a study and decision by the relevant authorities

 

Third, the pressure and stopping time of the strength test and the gas tightness test shall be in accordance with the design or technical documentation of the equipment.

 

Dear Air Separation has reliable safety measures in place for all tests of small air separation units, which are required to comply with the provisions of the air separation unit design and technical documentation.旋转 DSC03535

DEAR Air Separation Solve YourWhat are the requirements for strength and airtightness tests before the small air separation unit is put in place?  You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The plant operation cycle between two large heating is related to many factors. From an operational point of view, this mainly depends on when the air passage of the main heat exchanger is blocked. The main reason for the blockage is that the moisture and carbon dioxide content in the air entering the unit exceeds the standard, which accumulates and freezes in the main heat exchanger until it is blocked. The abnormal operation of molecular sieve purification system will shorten the operation cycle of the unit. It is mainly caused by the following reasons: 1. The molecular sieve adsorption bed is short circuited. In the process of operation, due to the unstable gas velocity control or switching, the pressure difference between the two tanks is too large, which will affect the bed layer, make the molecular sieve bed uneven and make the bed layer short circuit. In serious cases, the dust screen of the adsorber will break and the molecular sieve powder will enter the heat exchanger c
2026.03.30
What is the oxygen internal compression process
2026.03.27
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top