当前位置: Home / Faq / Large air separation FAQ /

Principles of heat exchanger channel allocation and arrangement of large air separation unit 

Principles of heat exchanger channel allocation and arrangement of large air separation unit 
Dec 03, 2021
Author: DEAR AST

The arrangement and distribution of multi-stream heat exchanger channel directly affect the heat transfer effect, and also the key to the design and manufacture of multi-stream heat exchanger and difficult point. All designs should follow certain principles and should not be designed at random. The general principles are: the same wall of the heat exchanger on both sides of the temperature as close as possible; the same fluid resistance of each channel is approximately the same; the channel is symmetrical in principle, so that it can be used for installation and manufacturing, while the forces are also the most appropriate.

 

Dear Air Separation brings together a large number of technical research and development talents such as American doctors and masters, the research centre has senior technical mechanics, and also has a number of design experts who enjoy reputations in the industry in China. All the above is to ensure the technical advancement of our products.3

DEAR Air Separation Solve YourPrinciples of heat exchanger channel allocation and arrangement of large air separation unit You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process. Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area. The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g). Deere air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the w
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top