The amount of carbon dioxide with a small air separation unit  

The amount of carbon dioxide with a small air separation unit  
Jan 03, 2025
Author: DEAR AST

The volume fraction of carbon dioxide in air is generally around 0.03%, if the air compressor compresses the air to 0.62 MPa, the partial pressure of carbon dioxide can be calculated as 186 Pa. At the temperature when the air enters the air separation device, the saturated vapor pressure of carbon dioxide is much higher than the partial pressure of carbon dioxide, so carbon dioxide is in an unsaturated state, and carbon dioxide in the air will not be precipitated in advance. Therefore, all carbon dioxide in the air is carried into the small air separation unit.

 

With comprehensive strength to create high quality air separation products, Dear Air Separation relies on the integrity of corporate character to win rich customer resources. For a long time, Dear Air Separation has been building air separation products by virtue of its strong comprehensive strength, and winning rich customer resources by virtue of its honest and trustworthy corporate character. For a long time, Dear Air Separation has been adhering to the principle of contract-abiding and trustworthy, and has made achievements over the years, including a number of loyal customer groups, and won a good reputation in the air separation industry.

1

DEAR Air Separation Solve YourThe amount of carbon dioxide with a small air separation unit  You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
It should contact with the front and rear processes when the piston compressor is ready to stop, we should pay attention to the following sequence: first, cut off the gas supply slowly. In order to prevent the outlet pressure from rising after the gas supply is cut off, open the vent valve at the same time. For the oxygen compressor, the vent valve should be opened slowly, because excessive opening may produce static electricity and cause fire. Then, stop the motor. After the motor stops, turn off the circulating oil pump, grease injector motor and cooling water valve. However, there are also exception cases. For example, in case of emergency shutdown, in order to save time and prevent the accident from expanding, the power supply can be cut off immediately to stop the compressor with load.
2026.01.28
Why do gas nitrogen and liquid nitrogen coexist at the top of the distillation tower of an air separation plant
2026.01.27
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top