In fact, reflux ratio is a conventional saying. In practical calculation, it is divided into liquid gas ratio in distillation section and gas-liquid ratio in stripping section. The minimum reflux ratio is of course the same. When the number of trays and reflux ratio determine the purity of distillation products, the actual meaning is that the gas-liquid ratio of the stripping section and the number of trays in the stripping section determine the purity of high boiling point distillation products. The purity of low boiling point products is determined by the ratio of liquid to gas and the number of plates in the distillation section.

 

Now take the minimum gas-liquid ratio of the stripping section as an example to illustrate the calculation of the minimum reflux ratio. First, let's explain what the minimum gas-liquid ratio means. The first is infinite plate number, the second is pure high boiling point product, and the third is infinitesimal distillation driving force. It can be concluded from the above situation that the composition of the rising gas at the bottom of the stripping section is pure high boiling component without low boiling component, and the composition of the gas phase and liquid phase at the top of the stripping section is the composition of the distillation raw material and its equilibrium liquid phase.

DEAR Air Separation focuses on R & D, manufacturing and installation of various complete sets of air separation unit, and provides comprehensive services such as gas investment, EPC project contracting, unit operation management and bioenergy. DEAR Air Separation has the ability to design and produce more than 30 sets of large and medium-sized air separation unit annually, and has successfully served more than 1000 customers around the world.

 

Spend a lot of money to build intelligent production workshop, ensure product quality close to zero defects, improve the accuracy of biogas purification unit, shorten the scheduled cycle. At the same time, it has a number of patented technologies, of which two ultra-low pressure discharge energy-saving patents belong to the domestic leading level, which can reduce the energy consumption of biogas purification unit by 5% - 15%, and save operating costs.

DSC03519

 

Science and technology innovation + management innovation initiated the reform of the air separation industry mode, and developed the remote intelligent monitoring system with the help of Internet technology. Realize remote control, automatic data acquisition and analysis and other functions to achieve early detection and early warning of unit failure.

DEAR Air Separation Solve YourMinimum gas-liquid ratio in liquid air separation plantYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process. Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area. The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g). Deere air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the w
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top