How to reduce the exhaust temperature of piston compressor in air separation unit

How to reduce the exhaust temperature of piston compressor in air separation unit
Nov 25, 2020
Author: DEAR AST
Question Reply

When the exhaust temperature of the piston compressor is higher than the design value, the most direct impact is that the lubricating oil is carbonized, which leads to the compressor parts burned out because of not getting good lubrication. If the temperature of the compressor is too high during actual operation, the cause should be analyzed in time and corresponding preventive measures should be taken. The following methods can be used for reference in practice.

 

1.Reducing the inlet air temperature can directly reduce the exhaust temperature. Check the intercooler to ensure the cooling effect of the intercooler.

 

2.The installation of the valve and the selection of the spring should be standardized to ensure the normal operation of the valve and minimize the loss of inlet and outlet pressure.

 

3.Strengthen the cooling of cylinder to ensure the normal compression process index.

 

4.Internal leakage is the main reason for the increase of exhaust temperature.

 

5.For multistage compressor, the reason of high exhaust temperature is not single. When the exhaust temperature of a certain stage is reduced, the pressure ratio of the previous stage will increase and the exhaust temperature will rise. Therefore, comprehensive measures should be taken to strengthen the cooling before the stage, and appropriately increase the clearance volume of the stage, so that the pressure ratio of the stage will remain unchanged and the exhaust temperature of a certain stage can be reduced At the same time, it does not affect the exhaust temperature of the front and rear stages.

DEAR Air Separation Solve YourHow to reduce the exhaust temperature of piston compressor in air separation unitYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Generally, the actual cooling capacity of expander is always less than the theoretical cooling capacity. Under the same inlet and outlet pressure and inlet gas temperature, the lower the efficiency of expander, the smaller the unit refrigerant cooling capacity and the smaller the temperature drop efficiency of expander. The efficiency of expander depends on the size of various losses inside the expander. Due to the existence of various losses, the ability of gas to do external work is reduced in varying degrees. To sum up, the losses mainly include the following aspects: 1. When the air flow passes through the work wheel and the deflector, the loss caused by friction and air flow impact on the runner surface is called flow loss. 2. When the impeller is rotating, the friction heat generated by the gas around the wheel disc will increase the temperature of the gas, which is called friction blast loss. 3. When the gas passes through the deflector, the leakage from the gap bet
2025.11.07
The principle and function of molecular sieve purification system in air separation equipment?
2025.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top