Causes and effects of main condenser evaporator leakage

Causes and effects of main condenser evaporator leakage
Nov 25, 2025
Author: DEAR AST
Question Reply

When the main condenser evaporator leaks seriously, a large amount of high-pressure nitrogen will leak to the low-pressure oxygen side, and the pressure of the upper and lower columns and the purity of the product will change significantly until normal production cannot be maintained.

 

When the main condenser evaporator leaks slightly, the pressure of the upper and lower columns will not change significantly, and the purity of liquid oxygen in the main condenser evaporator will not decrease significantly. The common phenomenon is that the purity of the gas and liquid oxygen in the main condensing evaporator is very different, and the gas concentration is lower than that in equilibrium with liquid oxygen. For example, the concentration of liquid oxygen is 99% and that of gaseous oxygen is 96%, that 7 main cooling pipes were found to be leaking during maintenance.

 

The common causes of leakage are as follows:

 

1.Pipes are worn due to mutual vibration. For long tube condensing evaporator, there are thousands of copper tubes, the diameter of which is only 10 mm, the length of which is 8m, and the distance between the tubes is very small. In the process of operation, due to the impact and vibration of the air flow, it is easy to bend and deform in the middle of the pipe and rub against each other, and may wear for a long time.

 

2.The water in the pipe causes freezing and cracking. When the heating is not complete, especially when the small tubes are blocked, the chance of water accumulation will be formed, and it can not be blown away in the heating process. The water will freeze into ice at low temperature, and the volume will expand, which may cause the small pipe to freeze and crack.

 

3.The main condensing evaporator has a slight explosion in local area. When acetylene or hydrocarbons accumulate locally in the main cooler, explosion may occur under certain conditions. When such a slight explosion occurs, there is no external reaction, no sound can be heard, and it is usually undetectable at first. Only when the oxygen purity changes automatically and cannot be adjusted,can this situationhappen.

DEAR Air Separation Solve YourCauses and effects of main condenser evaporator leakageYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What is the enthalpy in the air separation plant?
2026.08.20
1. Before filling with pearlite, the water accumulated on the foundation surface of air separation unit must be removed, dried with hot air, and all manholes shall be closed. 2. When filling pearlite, all containers and pipes in the cold box should be inflated and kept at 50kPa pressure, then slightly open the valve of each meter pipeline, and all thermometers should be electrified to check whether the thermometer cable is damaged during the filling process. 3. The filled pearlite shall not be mixed with combustibles. 4. When filling with pearlite, coarse mesh or pearlite pouring device should be set at the manhole on the top of the cold box to prevent whole bag pearlite from entering the cold box. 5. After the pearlite is filled, the manhole shall be sealed.
2026.08.18
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top