Prevention measures for fire and explosion accidents

Prevention measures for fire and explosion accidents
Jan 07, 2025
Author: DEAR AST
Question Reply

1.According to the specific situation of the construction, formulate the fire protection scheme, establish and improve the fire safety system, and strictly abide by the operation rules.

 

2.Flammable and explosive materials such as paint and thinner shall not be stored in the project site.

 

3.The construction unit is not allowed to set up seasoning room in the project, and is not allowed to carry out paint allocation in the project.

 

4.No smoking is allowed in the construction site. A fire permit shall be issued and a special person shall be assigned to supervise the operation.

 

5.The operation site should be equipped with sufficient fire-fighting equipment.

 

6.During the construction period, the use of various open fire operations in the project shall be approved by the safety and environmental protection department of the construction unit, and sufficient fire-fighting materials and fire-fighting equipment shall be provided.

 

7.It is strictly forbidden to store oxygen cylinders and acetylene cylinders in the construction site.

 

8.During construction, the distance between oxygen cylinder and acetylene cylinder should be 10 meters away from the hot work point, and the distance between oxygen cylinder and acetylene cylinder should be more than 5 meters.

 

9.For electric and gas welding operations, fire permit shall be obtained, and special personnel shall be assigned to take care of them. Sufficient fire fighting equipment shall be provided at the construction site.

 

10.The operators must hold the work license, apply for the fire permit at the relevant personnel of the project management department, clean up the inflammable and explosive materials in the operation area according to the requirements, and take measures to block the holes that may splash sparks.

DEAR Air Separation Solve YourPrevention measures for fire and explosion accidentsYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top