Cooling capacity balance of air separation cold box

Cooling capacity balance of air separation cold box
Sep 23, 2024
Author: DEAR AST
Question Reply

During the normal operation of the air separation plant, the temperature of each part of the cold box should be kept in balance. However, due to the temperature difference at the hot end of the heat exchanger and the possibility of no heat transfer between the cold box and the environment, and some large-scale air separation plants may produce a small amount of liquid products, which will cause heat loss. Therefore, to supplement the lost cooling capacity through expander and throttling, we paid electric energy to get the cooling capacity of expander. Why can throttling produce cooling capacity? This is because the pressure decreases after throttling, and the throttled liquid air and liquid nitrogen are saturated liquid. The pressure drop naturally causes the saturation temperature to decrease. In order to maintain its saturation state, part of the liquid is gasified to absorb heat.

DEAR Air Separation Solve YourCooling capacity balance of air separation cold boxYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The nitrogen from the top of the upper tower is piped through the nitrogen gas pipeline, reheated through the main heat exchanger of the colder tower, and a portion of the nitrogen is pumped out, then combined with the first pipeline and a portion of the nitrogen vaporised in the liquefier in the third pipeline before going to the main vessel. The first raw material air pipeline is heated up and out of the cold box in liquid air separation plant, then goes to the high pressure heat exchanger of ...
2025.11.26
When the main condenser evaporator leaks seriously, a large amount of high-pressure nitrogen will leak to the low-pressure oxygen side, and the pressure of the upper and lower columns and the purity of the product will change significantly until normal production cannot be maintained. When the main condenser evaporator leaks slightly, the pressure of the upper and lower columns will not change significantly, and the purity of liquid oxygen in the main condenser evaporator will not decrease significantly. The common phenomenon is that the purity of the gas and liquid oxygen in the main condensing evaporator is very different, and the gas concentration is lower than that in equilibrium with liquid oxygen. For example, the concentration of liquid oxygen is 99% and that of gaseous oxygen is 96%, that 7 main cooling pipes were found to be leaking during maintenance. The common causes of leakage are as follows: 1. Pipes are worn due to mutual vibration. For long tube condensing evap
2025.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top