Cooling capacity balance of air separation cold box

Cooling capacity balance of air separation cold box
Sep 23, 2024
Author: DEAR AST
Question Reply

During the normal operation of the air separation plant, the temperature of each part of the cold box should be kept in balance. However, due to the temperature difference at the hot end of the heat exchanger and the possibility of no heat transfer between the cold box and the environment, and some large-scale air separation plants may produce a small amount of liquid products, which will cause heat loss. Therefore, to supplement the lost cooling capacity through expander and throttling, we paid electric energy to get the cooling capacity of expander. Why can throttling produce cooling capacity? This is because the pressure decreases after throttling, and the throttled liquid air and liquid nitrogen are saturated liquid. The pressure drop naturally causes the saturation temperature to decrease. In order to maintain its saturation state, part of the liquid is gasified to absorb heat.

DEAR Air Separation Solve YourCooling capacity balance of air separation cold boxYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Traditional LNG receiving stations use seawater open-frame vaporisers or submerged combustion vaporisers to vaporise LNG, which not only wastes valuable cold energy but also produces localised low temperature pollution of the nearby sea. The air separation temperature range is between -190C - 150C and the LNG vaporisation temperature is -162C, which matches the liquid air separation plant temperature range. The use of LNG's high quality low temperature cold energy for liquid air separation plant...
2025.10.31
The load regulation range of low pressure air separation unit is related to the regulating performance of feed air compressor, the regulating performance of expander and the structural characteristics of distillation column. At present, the flow regulation range of turbine air compressor with inlet guide vane is 75% to 100%, and that of turbocharged expander with adjustable nozzle is 65% to 100%. Next, the most important thing is to adjust the residual of the distillation column. At present, the load regulation range of distillation column with structured packing can reach 50% - 100%, while that of traditional sieve tray column is 70% - 100%. If the load is too low, it will cause liquid leakage because the speed of steam passing through the sieve is too slow. When oxygen is sufficient and the oxygen output needs to be reduced, first reduce the output of oxygen products, then reduce the air flow accordingly, and adjust the expansion air volume according to the main cooling level. The
2025.10.30
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top