Effect of precooling

Effect of precooling
Sep 20, 2024
Author: DEAR AST

In the air separation unit, since the raw air is compressed, the water in the air leaving the air compressor is generally saturated. After leaving the air cooling tower, the water in the air is still saturated. However, after passing the air cooling tower, the air temperature decreases and the water content in the saturated state decreases. Therefore, the air passing through the air cooling tower not only reduces the air temperature, but also reduces the water content in the air and reduces the load of molecular sieve.

Kaifeng DEAR Air Separation Group Design and Research Institute, through continuous research and development, has developed a device for producing low temperature clean air that is applied to YPN-2000 nitrogen external liquefaction equipment. The device removes dust and gas impurities from the air through a dust filter and an air purification mechanism, and regulates them through a turbine expander, a main heat exchanger and a three-way regulating valve to produce high-quality low temperature clean air whose temperature can be adjusted within a certain range, The problem of environmental pollution caused by refrigerant in cascade refrigeration system is solved, and the operation cost and cost are low, and the maintenance and operation are less difficult, which is conducive to mass production of high-quality low-temperature clean air.

DEAR Air Separation Solve YourEffect of precoolingYou can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process. Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area. The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g). Deere air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the w
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top