Effect of precooling

Effect of precooling
Sep 20, 2024
Author: DEAR AST

In the air separation unit, since the raw air is compressed, the water in the air leaving the air compressor is generally saturated. After leaving the air cooling tower, the water in the air is still saturated. However, after passing the air cooling tower, the air temperature decreases and the water content in the saturated state decreases. Therefore, the air passing through the air cooling tower not only reduces the air temperature, but also reduces the water content in the air and reduces the load of molecular sieve.

Kaifeng DEAR Air Separation Group Design and Research Institute, through continuous research and development, has developed a device for producing low temperature clean air that is applied to YPN-2000 nitrogen external liquefaction equipment. The device removes dust and gas impurities from the air through a dust filter and an air purification mechanism, and regulates them through a turbine expander, a main heat exchanger and a three-way regulating valve to produce high-quality low temperature clean air whose temperature can be adjusted within a certain range, The problem of environmental pollution caused by refrigerant in cascade refrigeration system is solved, and the operation cost and cost are low, and the maintenance and operation are less difficult, which is conducive to mass production of high-quality low-temperature clean air.

DEAR Air Separation Solve YourEffect of precoolingYou can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
According to the daily water quality analysis and laboratory results, supplement the discharge water and control the dosing amount to make it reach the required data index. When the turbidity is >20mgL, increase the amount of drainage water, increase the flow of side filtration, and supplement clean water. According to the current situation of the circulating water system, try to increase the concentration multiple operation to save water and medicine. If the concentration multiplier is g...
2026.09.04
Before the air cooling columnand water cooling columnare hoisted in place, the anchor hole shall be cleaned, and there shall be no water and debris in the anchor hole.   After the air cooling columnand water cooling columnare hoisted in place, the perpendicularity of the equipment shall be checked. The perpendicularity shall be ≤ 1/1000 and the total length shall not exceed 10mm.   The bottom of the anchor bolt shall not touch the bottom of the reserved anchor hole. Af...
2026.09.03
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top