Effect of precooling

Effect of precooling
Sep 20, 2024
Author: DEAR AST

In the air separation unit, since the raw air is compressed, the water in the air leaving the air compressor is generally saturated. After leaving the air cooling tower, the water in the air is still saturated. However, after passing the air cooling tower, the air temperature decreases and the water content in the saturated state decreases. Therefore, the air passing through the air cooling tower not only reduces the air temperature, but also reduces the water content in the air and reduces the load of molecular sieve.

Kaifeng DEAR Air Separation Group Design and Research Institute, through continuous research and development, has developed a device for producing low temperature clean air that is applied to YPN-2000 nitrogen external liquefaction equipment. The device removes dust and gas impurities from the air through a dust filter and an air purification mechanism, and regulates them through a turbine expander, a main heat exchanger and a three-way regulating valve to produce high-quality low temperature clean air whose temperature can be adjusted within a certain range, The problem of environmental pollution caused by refrigerant in cascade refrigeration system is solved, and the operation cost and cost are low, and the maintenance and operation are less difficult, which is conducive to mass production of high-quality low-temperature clean air.

DEAR Air Separation Solve YourEffect of precoolingYou can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In the process of operation, especially in the start-up and shutdown of the air separation unit, one-way force should be avoided on the instrument. During the start-up of the equipment, close the high pressure and low pressure valves firstly, then open the balance valve, and then slowly open the high pressure (or low pressure) valve, so that the measured medium can enter the positive (negative) pressure chamber of the transmitter. If the liquid is to be measured, the gas in the positive (negative) pressure chamber should be discharged from the upper vent. If the gas is measured, drain the liquid accumulated in the positive (negative) pressure chamber from the lower drain screw hole. After discharging the gas (liquid), close the balance valve, and then open the valve on the other side. When the equipment is shut down, the high pressure (or low pressure) valve should be closed first, then the balance valve should be opened, and then the valve should be closed on the other side. Someti
2026.07.31
What are the reasons why the oxygen production of air separation equipment cannot meet the target
2026.07.30
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top