Effect of precooling

Effect of precooling
Sep 20, 2024
Author: DEAR AST

In the air separation unit, since the raw air is compressed, the water in the air leaving the air compressor is generally saturated. After leaving the air cooling tower, the water in the air is still saturated. However, after passing the air cooling tower, the air temperature decreases and the water content in the saturated state decreases. Therefore, the air passing through the air cooling tower not only reduces the air temperature, but also reduces the water content in the air and reduces the load of molecular sieve.

Kaifeng DEAR Air Separation Group Design and Research Institute, through continuous research and development, has developed a device for producing low temperature clean air that is applied to YPN-2000 nitrogen external liquefaction equipment. The device removes dust and gas impurities from the air through a dust filter and an air purification mechanism, and regulates them through a turbine expander, a main heat exchanger and a three-way regulating valve to produce high-quality low temperature clean air whose temperature can be adjusted within a certain range, The problem of environmental pollution caused by refrigerant in cascade refrigeration system is solved, and the operation cost and cost are low, and the maintenance and operation are less difficult, which is conducive to mass production of high-quality low-temperature clean air.

DEAR Air Separation Solve YourEffect of precoolingYou can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The nitrogen from the top of the upper tower is piped through the nitrogen gas pipeline, reheated through the main heat exchanger of the colder tower, and a portion of the nitrogen is pumped out, then combined with the first pipeline and a portion of the nitrogen vaporised in the liquefier in the third pipeline before going to the main vessel. The first raw material air pipeline is heated up and out of the cold box in liquid air separation plant, then goes to the high pressure heat exchanger of ...
2025.11.26
When the main condenser evaporator leaks seriously, a large amount of high-pressure nitrogen will leak to the low-pressure oxygen side, and the pressure of the upper and lower columns and the purity of the product will change significantly until normal production cannot be maintained. When the main condenser evaporator leaks slightly, the pressure of the upper and lower columns will not change significantly, and the purity of liquid oxygen in the main condenser evaporator will not decrease significantly. The common phenomenon is that the purity of the gas and liquid oxygen in the main condensing evaporator is very different, and the gas concentration is lower than that in equilibrium with liquid oxygen. For example, the concentration of liquid oxygen is 99% and that of gaseous oxygen is 96%, that 7 main cooling pipes were found to be leaking during maintenance. The common causes of leakage are as follows: 1. Pipes are worn due to mutual vibration. For long tube condensing evap
2025.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top