Factors affecting the performance of main heat exchanger

Factors affecting the performance of main heat exchanger
Dec 31, 2025
Author: DEAR AST
Question Reply

The main heat exchanger is the key equipment to ensure the performance of the air separation plant. Its functions in the air separation plant of the molecular sieve pre-filtration process are as follows: recover the cooling capacity of the reflux gas, ensure that the heat exchange temperature difference is within the design range; provide sufficient expansion gas in front of the expander to make up for the cooling loss of the air separation plant; provide raw air for the lower tower under the design conditions; and the working medium is in the main heat exchanger The resistance value in meets the process requirements.

 

In the air separation plant, all factors affecting the performance of the equipment will be reflected in the main heat exchanger. Therefore, we always start from the suspected design of the main heat exchanger to carry out troubleshooting, and correctly analyze the external factors affecting the performance of the main heat exchanger is the shortcut to solve the problems of the air separation plant. According to the long-term practical experience, the main factors affecting the performance of the main heat exchanger are as follows:

 

1.Expander efficiency: the air compressor's exhaust volume is given by the process. If the expansion air volume increases, the positive flow air volume will decrease, which will reduce the heat load at the cold end of the main heat exchanger, and the cooling capacity will move up to the hot end. If there is excess cooling capacity at the hot end, the temperature difference at the hot end of the main heat exchanger will increase.

 

2.Molecular sieve adsorber: when the molecular sieve adsorber has insufficient filling amount, uneven bed, incomplete regeneration of molecular sieve, poor adsorption performance of molecular sieve, structural defects and other reasons, resulting in air short circuit, and molecular sieve leakage due to manufacturing problems, the adsorption of moisture and CO2 in the air will be affected, resulting in the increase of temperature difference and resistance at the hot end of the main heat exchanger.

 

3.Cooling loss: one part of the cooling loss of the distillation column system of the air separation plantis the loss of insufficient reheating of the main heat exchanger, and the other part is the cooling loss of the external environment of the equipment. The loss of reheating deficiency is determined by the temperature difference at the hot end of the main heat exchanger and set by the process flow; while the loss of cooling loss is estimated by experience, which is a process parameter. The difference between the set value of cooling loss and the actual value in operation also directly affects the temperature difference at the hot end of the main heat exchanger.

DEAR Air Separation Solve YourFactors affecting the performance of main heat exchangerYou can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: Dier air separation (Kaifeng Dier air separation Industrial Co., Ltd.) -- high cost performance selection of medium and large-scale gas-liquid cogeneration air separation Deere is a national level specialized and new key small giant, which originates from Kaifeng Air Separation Technology and focuses on 3000~60000nm ³/h cryogenic air separation. Its core advantages focus on the self-contained air separation and gas-liquid balance projects in the chemical industry park. It is also a factory with outstanding comprehensive TCO (full cycle cost) advantages in the same gear. Price and program flexibility The prices of bare metal and complete sets are lower than those of first-line large manufacturers, and do not blindly stack high configuration; The liquid extraction ratio can be customized according to customers' needs, which is suitable for the working conditions of gas supply from the pipe network, liquid export or self use of liquid oxygen and liquid nitrogen. The liquid extract
2026.11.09
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top