Judgment of cooling capacity balance of distillation column in air separation plant

Judgment of cooling capacity balance of distillation column in air separation plant
Oct 15, 2024
Author: DEAR AST
Question Reply

In order to ensure the stable operation of the distillation column, the in and out material and its state of the distillation column needs to meet the material balance, component balance and energy balance. The main cooling liquid oxygen surface is an important indicator of whether the cooling capacity of the air separation plant is balanced or not. When the cooling loss of the unit is greater than the cooling capacity, the moisture content of the air entering and leaving the column (the liquid content in the saturated air) will be reduced, and the nitrogen to be condensate in main cooling needs to be condensed, the evaporation of liquid oxygen will also increase, and the surface of liquid oxygen will decrease. On the contrary, when the cooling capacity is greater than the cooling loss of the unit, the moisture content of the air entering the lower column will increase, and the amount of nitrogen to be condensed in the main cooling system will decrease, and the liquid oxygen surface will naturally increase.

DEAR Air Separation Solve YourJudgment of cooling capacity balance of distillation column in air separation plantYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What requirements and regulations should be met for the assembly of meter tube, cold insulation box and strength and air tightness test before positioning of air separation equipment
2025.01.08
1. According to the specific situation of the construction, formulate the fire protection scheme, establish and improve the fire safety system, and strictly abide by the operation rules. 2. Flammable and explosive materials such as paint and thinner shall not be stored in the project site. 3. The construction unit is not allowed to set up seasoning room in the project, and is not allowed to carry out paint allocation in the project. 4. No smoking is allowed in the construction site. A fire permit shall be issued and a special person shall be assigned to supervise the operation. 5. The operation site should be equipped with sufficient fire-fighting equipment. 6. During the construction period, the use of various open fire operations in the project shall be approved by the safety and environmental protection department of the construction unit, and sufficient fire-fighting materials and fire-fighting equipment shall be provided.
2025.01.07
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top