Treatment of cooler leakage after boosting of expander

Treatment of cooler leakage after boosting of expander
Jun 13, 2025
Author: DEAR AST
Question Reply

According to a DEAR air separation user, during the operation of a set of air separation plant that has been in operation for 5 years, it is found that under the condition that the inlet guide vane does not change, the expansion air volume of the expander gradually decreases, and the rotation speed of the expander gradually decreases, the outlet pressure of the booster end of the expander rises from 0.76MPa to 0.8MPa, the inlet temperature rises from - 110 ° C to - 95 ° C, and the working condition of the chilled water pump is poor.

According to the situation reported by the user, DEAR air separation sent technicians to the site in time, switched 2# standby expanders immediately according to the situation on the site, and checked the faulted 1# expander. By closing the inlet and outlet valves of the aftercooler of 1# expander booster, it is found that there is always gas discharged from the exhaust valve on the water side of the cooler after water drainage, so as to determine the leakage of the cooler.

Because the water pressure of the cooler is basically the same as the air pressure, water is carried on the air side during operation, and it is frozen on the charge air channel of the main heat exchanger and the inlet filter of the expander, which results in poor heat exchange effect of the main heat exchanger channel, temperature rise at the inlet of the expander and decrease of the expansion air volume.

After determined the cause of failure, the 1# expander after supercharging cooler is disassembled and inspected, and two heat exchange tubes (made of carbon steel) are found to be leaking. Then we blocked the leaking heat exchange tubes. After pressure test, they meet the use conditions. After reassembly, they are temporarily restored to use.

In order to fundamentally solve the problem and prevent the leakage from happening again, it is recommended that the user replace the tube bundle of the aftercooler, change the carbon steel heat exchange tube which is easy to be corroded into the stainless steel heat exchange tube; in operation, reasonable operation steps are formulated to ensure that the pressure at the gas side is always higher than that at the water side. The acidity, alkalinity and hardness of the chilled water should be tested regularly, and the water supplement amount of the water cooling column should be increased regularly. The dry expansion air is used to take the water on the booster channel of the main heat exchanger to the inlet filter of the expander, and the water is taken out of the device by heating the expander.

Through the above operation and improvement, the normal operation function of the equipment is restored, and the shutdown and heating of the air separation plant are avoided.

DEAR Air Separation Solve YourTreatment of cooler leakage after boosting of expanderYou can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The molecular sieve used in oxygen generators is the zeolite molecular sieve. It is a crystalline silica and aluminate polyhydric compound. Molecular sieves have a uniform pore size and their main function is to sieve molecules. There are three main types of molecular sieves: A, X and Y. The 13X molecular sieve is the only adsorbent currently used in liquid air separation plants. Any molecules that can be adsorbed on 3A, 4A and 5A molecular sieves can be adsorbed by 13X molecular sieves. It is c...
2026.09.30
Pressure test before valve installation 1. In the warranty period, those with the certification and the sealing surface is intact can no longer conduct the strength test alone, but only the air tightness test can be taken before installation. 2. Within the warranty period, it has the certificate, and its sealing surface has defects such as corrosion and damage. After treatment, it must carry out the air tightness test. 3. Outside the warranty period, those with certification and intact sealing surface shall be subject to air tightness test before installation. 4. For valves that need to be degreased and disassembled on site, air tightness test shall be conducted separately before installation. 5. The safety valve shall be sent to the local quality inspection department of the project for verification before the end of installation and commissioning.
2026.09.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top