Treatment of cooler leakage after boosting of expander

Treatment of cooler leakage after boosting of expander
Jun 13, 2025
Author: DEAR AST
Question Reply

According to a DEAR air separation user, during the operation of a set of air separation plant that has been in operation for 5 years, it is found that under the condition that the inlet guide vane does not change, the expansion air volume of the expander gradually decreases, and the rotation speed of the expander gradually decreases, the outlet pressure of the booster end of the expander rises from 0.76MPa to 0.8MPa, the inlet temperature rises from - 110 ° C to - 95 ° C, and the working condition of the chilled water pump is poor.

According to the situation reported by the user, DEAR air separation sent technicians to the site in time, switched 2# standby expanders immediately according to the situation on the site, and checked the faulted 1# expander. By closing the inlet and outlet valves of the aftercooler of 1# expander booster, it is found that there is always gas discharged from the exhaust valve on the water side of the cooler after water drainage, so as to determine the leakage of the cooler.

Because the water pressure of the cooler is basically the same as the air pressure, water is carried on the air side during operation, and it is frozen on the charge air channel of the main heat exchanger and the inlet filter of the expander, which results in poor heat exchange effect of the main heat exchanger channel, temperature rise at the inlet of the expander and decrease of the expansion air volume.

After determined the cause of failure, the 1# expander after supercharging cooler is disassembled and inspected, and two heat exchange tubes (made of carbon steel) are found to be leaking. Then we blocked the leaking heat exchange tubes. After pressure test, they meet the use conditions. After reassembly, they are temporarily restored to use.

In order to fundamentally solve the problem and prevent the leakage from happening again, it is recommended that the user replace the tube bundle of the aftercooler, change the carbon steel heat exchange tube which is easy to be corroded into the stainless steel heat exchange tube; in operation, reasonable operation steps are formulated to ensure that the pressure at the gas side is always higher than that at the water side. The acidity, alkalinity and hardness of the chilled water should be tested regularly, and the water supplement amount of the water cooling column should be increased regularly. The dry expansion air is used to take the water on the booster channel of the main heat exchanger to the inlet filter of the expander, and the water is taken out of the device by heating the expander.

Through the above operation and improvement, the normal operation function of the equipment is restored, and the shutdown and heating of the air separation plant are avoided.

DEAR Air Separation Solve YourTreatment of cooler leakage after boosting of expanderYou can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top