Cause analysis and elimination method of excessive liquid nitrogen and oxygen content in liquid nitrogen storage tank

Cause analysis and elimination method of excessive liquid nitrogen and oxygen content in liquid nitrogen storage tank
Sep 13, 2024
Author: DEAR AST
Question Reply

A user of DEAR air separation reflected that when the air separation plant was put into operation, a large liquid nitrogen storage tank was equipped for emergency backup when the air separation was stopped or export of liquid products. The value of oxygen content in nitrogen product is designed to be less than 3ppm (i.e., < 3 ×10-6) due to the high requirement of users for nitrogen purity. But in fact, the oxygen content of liquid nitrogen in the tanks had been found more than 5ppm. The substandard purity of liquid nitrogen not only affects the export of products, but also directly affects the emergency backup of liquid nitrogen backup system.

 

On-site observation by DEAR air separation technician: in the process design, when the air separation plant is started or shut down, the liquid nitrogen feeding valve HV3207 is closed before the liquid nitrogen purity is qualified, and it is forbidden to enter the storage tank. In theory, there is no possibility that the liquid nitrogen purity is not up to the standard. But in fact, in the process of start-up or shut-down, the phenomenon of high liquid nitrogen oxygen content in the storage tank has occurred for many times.

 

Through the actual observation and analysis, it is found that the reasons for the excessive content of liquid nitrogen and oxygen are as follows:

 

1.HV3207 valve has internal leakage. When the plant is started orshut down, the operator often wrongly thinks that the process of liquid nitrogen entering the storage tank has been cut off, and the manual valve 7306 of liquid nitrogen entering the tank has not been closed in time, resulting in unqualified liquid nitrogen entering the storage tank;

 

2.During the plant start-up orshut-down, the working condition fluctuates greatly, and the range of the pressure controller of the gas-liquid separator is too small to be adjusted. Once the pressure of the gas-liquid separator is lower than the pressure of the upper column, the impure gas nitrogen of the upper columnflows back into the gas-liquid separator, which reduces the purity of the liquid nitrogen;

 

3.The pipeline of liquid nitrogen entering the storage tank is not completely replaced, which makes the residual oxygen components in the pipeline enter the storage tank.For theabove situation, the user is required to take the following measures: standardize the operation of valve 7306, close valve 7306 immediately and slightly open valve 7320 when HV3207 valve is closed automatically due to unqualified liquid nitrogen purity during equipment start-up or shut-down, to prevent unqualified liquid nitrogen from entering the storage tank; expand the range of pressure controller of gas-liquid separator, and switch valve PV3207 to manual mode and turn down in time when plant start-up or shut-down, to ensure that the pressure in the gas-liquid separator is not lower than the upper column pressure; completely replace the pipeline of liquid nitrogen into the tank.

 

Through the improvement of operation method, in the later operation, the occurrence of nitrogen purity exceeding the standard is avoided. The quality of liquid nitrogen products are guaranteed to be exported and stored.

DEAR Air Separation Solve YourCause analysis and elimination method of excessive liquid nitrogen and oxygen content in liquid nitrogen storage tankYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In medium and large air separation plants, the purification system is an important part when separating oxygen, nitrogen and argon from air. The purification system commonly uses molecular sieve adsorbent to adsorb moisture, carbon dioxide, hydrocarbons, etc. in the air. The molecular sieve purification system plays an important role in the air separation equipment process to ensure safety. The molecular sieve purification system is generally composed of adsorber, electric heater, pipeline, val...
2025.12.12
When the exhaust temperature of the piston compressor is higher than the design value, the most direct impact is that the lubricating oil is carbonized, which leads to the compressor parts burned out because of not getting good lubrication. If the temperature of the compressor is too high during actual operation, the cause should be analyzed in time and corresponding preventive measures should be taken. The following methods can be used for reference in practice. 1. Reducing the inlet air temperature can directly reduce the exhaust temperature. Check the intercooler to ensure the cooling effect of the intercooler. 2. The installation of the valve and the selection of the spring should be standardized to ensure the normal operation of the valve and minimize the loss of inlet and outlet pressure. 3. Strengthen the cooling of cylinder to ensure the normal compression process index. 4. Internal leakage is the main reason for the increase of exhaust temperature. 5.For multist
2025.12.11
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top