Air separation equipmentDuring the process of manufacturing, argon arc welding will produce harmful gas and high frequency electricity, so there are several protection and safety measures as follows:
1) tungsten manual argon arc welding currently uses tungsten tungsten with a small amount of radioactive as the electrode. When welding in a closed place or with large current, ventilation and special protective mask should be strengthened.
2) when grinding the end of tungsten pole with grinding wheel due to the need of work, there must be good ventilation because there are radioactive particles in the dust. And the staff should wear masks. It is better to use mechanized closed grinding tungsten pole device.
3) the ultraviolet intensity of argon arc welding is 5 ~ stronger than that of manual arc welding ~ 19 times. In order to prevent intense ultraviolet radiation from harming eyes and skin, wear a mask, white work clothes and gloves when welding, and do not roll up the cuff.
4) in order to reduce the influence of high frequency electricity on human body during welding, the outside of welding cable of welding gun should be shielded by soft metal wire woven hose. One end of the hose is connected to the welding gun, and the other end is grounded without insulation outside. In addition, in order to prevent electric shock, insulation rubber should be added to the ground near the workbench, and the staff should wear insulation rubber shoes.
5) the harmful gases produced by argon arc welding are mainly ozone, NOx and metal dust, so the workplace of argon arc welding should have good natural ventilation and mechanical ventilation devices.

DEAR Air Separation Solve YourWhat safety issues should be paid attention to when conducting argon arc welding?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top