Water cooling towerIt is a hybrid heat exchanger. The purpose is to lower the temperature of cooling water in the cooling tower after cooling the air, so that the air cooling tower can be recycled. Different types strive to enhance heat transfer, improve cooling effect, and at the same time, flow resistance should be as small as possible, so that water is not easy to scale.
Large scale in ChinaAir separation equipmentThe structure of water cooling tower selected is roughly in the following types:

1) stuffing tower. In the early stage, it was a Laci ring with porcelain. Its heat transfer effect was good and the resistance was not big. However, when it is used in the process of self-clearing low pressure, because the switching system is switched once every few minutes, when the switching is emptied, the impact of airflow on the porcelain ring is relatively large, which is easy to cause the damage of the porcelain ring and increase the resistance. Some are also changed into plastic rings to increase the strength. Currently at 6000 ~ 40000m3A new type of stuffing tower is used on the air separation plant of/h, which adopts Alpha ball ring or common ring and ladder ring. It has the advantages of large flux, small resistance, good heat transfer effect and good strength. The temperature difference of heat transfer at the hot end is about 0.5 ℃, and the negative temperature difference of effluent (the temperature of water is lower than that of nitrogen) can reach 4 ~ 9 ℃, depending on the gas-liquid ratio.

2) swirling plate. It is composed of several metal structure swirling Tower plates. This kind of structural resistance is very small and will not be damaged. It has been used as an improved type for quite a long time. But the heat transfer effect than packed tower.

3) sieve tower. The tower plate adopts drench Tower plate with larger aperture and hole spacing. Both nitrogen and water pass through the sieve hole. Since the water cooling tower does not work continuously and stably, the cooling effect is not ideal enough, so it is no longer used now.

DEAR Air Separation Solve YourWhat types of water cooling tower are there?You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top