How does the flow integrator calculate the flow in a certain period of time?

How does the flow integrator calculate the flow in a certain period of time?
Sep 13, 2023
Author: DEAR AST
Question Reply

Air separation equipmentThe medium flow integrator is used together with the flow meter and accumulates the total amount of fluid flowing through the pipeline within a certain period of time. The usage of the integrator is as follows:
1) calculate the integral constant K. The meaning of K is the traffic value represented by each word (unit count) of the integrator.
K=qv,max/R
In the formula, qv, max -- the maximum scale of the flow meter matched with the integrator;
R -- when the input flow is qv, max, the number of words passed by the integrator within 1 hour is called integrator constant.
2) calculate the traffic. In a certain time interval, the difference of two reading times of the integrator multiplies the integral constant K, which is the total flow during this period of time. Use formula to express:
qv=(R2-R1)K
K in the formula -- integral constant:
R1 -- the first reading of the integrator;
R2 -- second reading of integrator.
For example, when the maximum scale of the flow meter used by the product oxygen flow integrator of 6000m3/h oxygen generator is 8000m3/h, the constant R of the integrator is selected to be 400. I walked 2440 words within 8 hours. Then the integral constant is: K = 8000/400 = 20m3/word.
The total output of oxygen within 8 hours is:
Qv=2440×20=48800m3
The average oxygen production per 1 H is:
qv=48800/8=6100m3/h

DEAR Air Separation Solve YourHow does the flow integrator calculate the flow in a certain period of time?You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
1. Before filling with pearlite, the water accumulated on the foundation surface of air separation unit must be removed, dried with hot air, and all manholes shall be closed. 2. When filling pearlite, all containers and pipes in the cold box should be inflated and kept at 50kPa pressure, then slightly open the valve of each meter pipeline, and all thermometers should be electrified to check whether the thermometer cable is damaged during the filling process. 3. The filled pearlite shall not be mixed with combustibles. 4. When filling with pearlite, coarse mesh or pearlite pouring device should be set at the manhole on the top of the cold box to prevent whole bag pearlite from entering the cold box. 5. After the pearlite is filled, the manhole shall be sealed.
2026.08.18
What is the oxygen extraction rate?
2026.08.17
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top