What factors are related to the load regulation range of low-voltage air separation plant

What factors are related to the load regulation range of low-voltage air separation plant
Jul 10, 2023
Author: DEAR AST
Question Reply

Low-voltageAir separation equipmentThe load adjustment range is related to the adjustment performance of the raw material air compressor, the adjustment performance of the expansion machine, the structural characteristics of the distillation column and other factors. At present, there is a turbine with imported guide bladesAir compressorThe flow regulation range is 75% ~ 100%; the adjustment range of turbine expansion machine with adjustable nozzle can be 65% ~ 100%. The key is how much room for adjustment of the distillation column is. At present, the load regulation range of the distillation column with regular stuffing can reach 50% ~ 100%, while the best adjustment range of traditional screen tower is 70% ~ 100%, no matter how low the load is, the leakage may be caused by the low speed of steam passing through the sieve hole.
When oxygen is rich and needs to reduce the output of oxygen, the output of oxygen products should be reduced first, then the air flow should be reduced correspondingly, and the inflated air volume should be adjusted according to the main cold liquid level. The liquid air and liquid nitrogen regulating valve sent to the upper tower should also be cut down correspondingly according to the rectification working condition. It should be noted that the whole operation should be completed slowly and step by step to keep the stability of the rectification working condition in the process of reduction.
If there is a liquid oxygen storage system, reducing the output of oxygen can increase the output of liquid oxygen, making it more convenient to store liquid oxygen. We can reduce the output of oxygen first, then increase the expansion air volume, and increase the amount of liquid oxygen extraction under the condition of keeping the main cold liquid level unchanged. In order to keep the stability of the rectification working condition of the upper tower, part of the expansion air can be bypass if necessary.

DEAR Air Separation Solve YourWhat factors are related to the load regulation range of low-voltage air separation plantYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Gas blockage of centrifugal liquid oxygen pump
2024.10.31
When the air is out of the air compressor, due to the compression, the moisture in the air is in the saturated state. After the water cooling column decreasing the temperature, the water content in the saturated state decreases, and the excess water condenses into the water. The water volume in the air cooling column increases and the water temperature rises. But not only is the temperature of the air reduced, but also the moisture content of the air. In the water cooling column, the crude nitrogen is used to cool the water. After passing through the main heat exchanger from the fractionator, the temperature of the crude nitrogen is close to the normal temperature, but it is very dry. The dry crude nitrogen contacts with the water, and a large amount of water is evaporated into the crude nitrogen by using the unsaturation of the crude nitrogen, which absorbs the heat of the water and reduces the water temperature.
2024.10.30
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top