What factors are related to the load regulation range of low-voltage air separation plant

What factors are related to the load regulation range of low-voltage air separation plant
Jul 10, 2023
Author: DEAR AST
Question Reply

Low-voltageAir separation equipmentThe load adjustment range is related to the adjustment performance of the raw material air compressor, the adjustment performance of the expansion machine, the structural characteristics of the distillation column and other factors. At present, there is a turbine with imported guide bladesAir compressorThe flow regulation range is 75% ~ 100%; the adjustment range of turbine expansion machine with adjustable nozzle can be 65% ~ 100%. The key is how much room for adjustment of the distillation column is. At present, the load regulation range of the distillation column with regular stuffing can reach 50% ~ 100%, while the best adjustment range of traditional screen tower is 70% ~ 100%, no matter how low the load is, the leakage may be caused by the low speed of steam passing through the sieve hole.
When oxygen is rich and needs to reduce the output of oxygen, the output of oxygen products should be reduced first, then the air flow should be reduced correspondingly, and the inflated air volume should be adjusted according to the main cold liquid level. The liquid air and liquid nitrogen regulating valve sent to the upper tower should also be cut down correspondingly according to the rectification working condition. It should be noted that the whole operation should be completed slowly and step by step to keep the stability of the rectification working condition in the process of reduction.
If there is a liquid oxygen storage system, reducing the output of oxygen can increase the output of liquid oxygen, making it more convenient to store liquid oxygen. We can reduce the output of oxygen first, then increase the expansion air volume, and increase the amount of liquid oxygen extraction under the condition of keeping the main cold liquid level unchanged. In order to keep the stability of the rectification working condition of the upper tower, part of the expansion air can be bypass if necessary.

DEAR Air Separation Solve YourWhat factors are related to the load regulation range of low-voltage air separation plantYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In case of sudden power failure during the operation of small air separation unit, the following steps should be followed:   First, open the vent valve (anti surge valve) of air compressor to prevent the air compressor from surging and causing the air compressor to reverse due to air backflow;   Then check whether the molecular sieve adsorber switch should be interlocked to close, if not, it should be man...
2024.11.21
How is the ratio of individual gases adjusted in an air separation plant?
2024.11.20
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top