Home / All Air Separation tags /

The harm of frequent start and stop of air separation unit

The harm of frequent start and stop of air separation unit
The hazards of frequent start-up and shut-down of air separation unit include reducing the reliability and service life of the air separation unit, destroying the stability of the system, and affecting the safe operation of the air separation unit and causing accidents. Air separation unit should be regularly maintained to avoid frequent start-up and shutdown.
News of The harm of frequent start and stop of air separation unit
More
Oct 14, 2020
On October 13, it was reported that Kaifeng DEAR air separation Industrial Co., Ltd. (hereinafter referred to as DEAR air separation) and Luoyang Zhon
Aug 21, 2020
On August 18, Kaifeng DEAR air separation project department organized Gansu Kaisheng Daming project kick-off meeting room on the first floor of the c
Albums of The harm of frequent start and stop of air separation unit
More
Solutions of The harm of frequent start and stop of air separation unit
More
Large air separation plant KDON-16000/35000 solution for metallurgical industry
Metallurgical industry is an industry to develop metal mineral resources and produce various kinds of raw materials for metal products. With the progress of science and technology, the metallurgical industry has new requirements for the process, process, management and application research and development of air separation plant. The air separation plant also has the following development trends: first, large-scale and cluster; second, the core technology is gradually localization; third, refinement, which needs to develop high-efficiency energy-saving technology for different application fields; fourth, highly automated and intelligent, reduce manual operation as far as possible, and gradually establish a remote monitoring system by using the rapid development of internet technology to collect in real time according to the operation data of air separation plant, using big data analysis to provide the best suggestions for users, etc. KDON (Ar) - 16000 / 35000, a large scale air separat
Small air separation plant KDON(Ar)-8000/16000-220 solution for metallurgical industry
DEAR air separation has provided a number of complete solutions for the metallurgical industry for many years, accumulated rich experience, and helped the efficient development of the metallurgical industry. With many years of service experience in the metallurgical industry, DEAR air separation provides customer with the small air separation plant KDON (Ar) - 8000 / 16000 / 220, which is mature technological, operating reliable, operating convenient, and energy saving intelligent, that is highly recognized by customers.
Faq of The harm of frequent start and stop of air separation unit
More
1. According to the specific situation of the construction, formulate the fire protection scheme, establish and improve the fire safety system, and strictly abide by the operation rules. 2. Flammable and explosive materials such as paint and thinner shall not be stored in the project site. 3. The construction unit is not allowed to set up seasoning room in the project, and is not allowed to carry out paint allocation in the project. 4. No smoking is allowed in the construction site. A fire permit shall be issued and a special person shall be assigned to supervise the operation. 5. The operation site should be equipped with sufficient fire-fighting equipment. 6. During the construction period, the use of various open fire operations in the project shall be approved by the safety and environmental protection department of the construction unit, and sufficient fire-fighting materials and fire-fighting equipment shall be provided.
Jan 07, 2025
1. The requirements of molecular sieve adsorber, electric heater and other equipment in place are the same as those of air cooling column of pre cooling system. 2. Process piping shall be constructed in strict accordance with relevant specifications and design and construction drawings. 3. The air tightness test shall be conducted before the valve is installed, and the test pressure and inspection standard shall be carried out according to the technical requirements of corresponding valves. 4. Pay attention to the direction of switch valve installation. V1201, V1202, V1207 and V1208 are front mounted valves, while V1203, V1204, V1205 and V1206 are reverse mounted valves. When the switch valve is installed, its shaft should be in a horizontal position, and the flange bolts should be evenly cross tightened. 5. The pipeline of pressure equalizing valve V1209 should have compensating bend.
Dec 11, 2024
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top