Structure of water cooling column

Structure of water cooling column
Jul 04, 2025
Author: DEAR AST

In the air separation unit, the water cooling column is a hybrid heat exchange equipment which uses the crude nitrogen to reduce the temperature of the cooling water from the air cooling column after cooling air, so as to provide the air cooling column with recycling. In the water cooling column, the crude nitrogen from the reversible heat exchanger (or accumulator) is 27-28 ℃ and the relative humidity is about 30%, while the temperature of the cooling water from the air cooling column is 35-45 ℃. When the crude nitrogen meets the hot water sprayed, it absorbs heat, thus reducing the water temperature. Generally, the structure of water cooling column is packed column, cyclone plate column and sieve plate column.

 

1.Packed column: at present, the Alpha Pall ringswith large flow capacity, small resistance, good heat transfer effect and high strength is generally selected as the packing of water cooling columnin China, which can ensure that the heat transfer temperature difference at the hot end is about 0.5 ℃, and the negative temperature difference of outlet water can reach 4-9 ℃.

 

2.The hydrocyclone plate type of water cooling columnis composed of several metal structure swirl columnplates, which has the characteristics of small resistance and not easy to be damaged, but the heat transfer effect is inferior to that of packed water cooling column.

 

3.The sieve plate type water cooling columnadopts the spray columnplate with larger pore diameter and hole spacing. Nitrogen and water pass through the sieve hole and exchange heat. Because the work of the water cooling column is not continuous and stable, the cooling effect of the sieve plate type water cooling column is not as good as that of the packing type water cooling column.

 

The best heat transfer effect and cooling effect should be ensured when choosing the type of water cooling column. At the same time, the flow resistance should be reduced to prevent limescale.

DEAR Air Separation Solve YourStructure of water cooling columnYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Generally, the actual cooling capacity of expander is always less than the theoretical cooling capacity. Under the same inlet and outlet pressure and inlet gas temperature, the lower the efficiency of expander, the smaller the unit refrigerant cooling capacity and the smaller the temperature drop efficiency of expander. The efficiency of expander depends on the size of various losses inside the expander. Due to the existence of various losses, the ability of gas to do external work is reduced in varying degrees. To sum up, the losses mainly include the following aspects: 1. When the air flow passes through the work wheel and the deflector, the loss caused by friction and air flow impact on the runner surface is called flow loss. 2. When the impeller is rotating, the friction heat generated by the gas around the wheel disc will increase the temperature of the gas, which is called friction blast loss. 3. When the gas passes through the deflector, the leakage from the gap bet
2025.11.07
The principle and function of molecular sieve purification system in air separation equipment?
2025.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top