What is the cause of ultra low temperature in air separation plant and the principle of refrigeration equipment?

What is the cause of ultra low temperature in air separation plant and the principle of refrigeration equipment?
Jul 28, 2026
Author: DEAR AST

The air separation unit realizes the ultra-low temperature required for air liquefaction. The core is based on the principle of low-temperature refrigeration cycle and gas expansion and heat absorption. The whole system gradually reduces the normal temperature air to minus 196 ℃ liquefaction temperature by combining mechanical refrigeration, heat exchange cooling and throttling refrigeration, providing a low-temperature basis for air rectification and separation. Low temperature air separation is not a single equipment refrigeration, but a comprehensive refrigeration system with multi-stage cooling, step-by-step cold storage and cold energy recovery.
The core refrigeration equipment of air separation is a turbo expander, which is the core device for producing ultra-low cooling capacity. Part of the high-pressure clean air compressed by the air compressor, cooled by the precooling unit and purified by molecular sieve enters the expander for high-speed expansion to do work. The gas pressure is rapidly reduced and the internal energy is sharply reduced, achieving severe adiabatic cooling and generating most of the cooling capacity required for equipment operation. At the same time, it is equipped with air throttle valve for auxiliary refrigeration. The high-pressure air is throttled and depressurized to further reduce the medium temperature and make up for the cooling consumption of the system.
The cooling capacity of the equipment is recycled through the main heat exchanger, and the low-temperature reflux dirty nitrogen and product gas precooling the incoming normal temperature air, greatly reducing the cooling capacity loss and continuously accumulating the low-temperature working conditions. In the production process, the expander continues to make up cooling, the heat exchanger maintains high-efficiency cooling, and the cooling capacity is recovered in a closed loop. The three are coordinated and balanced to maintain the ultra-low and low temperature environment in the air separation tower and ensure the continuous and stable operation of air liquefaction and distillation purification.

DEAR Air Separation Solve YourWhat is the cause of ultra low temperature in air separation plant and the principle of refrigeration equipment?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process. Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area. The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g). Deere air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the w
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top