What is the difference between air cooling tower and water cooling tower of air separation equipment?

What is the difference between air cooling tower and water cooling tower of air separation equipment?
May 27, 2026
Author: DEAR AST

In the air separation equipment, the air cooling tower and water cooling tower are supporting cooling equipment with similar structures, but there are obvious differences in working medium, purpose of action and source of cooling source, with clear division of work and mutual cooperation.
First, different working media. The heat exchange medium of the air cooling tower is compressed air and circulating cooling water, and the compressed air is mainly treated; The heat exchange medium of the water cooling tower is circulating water and low-temperature sewage nitrogen, mainly cooling circulating water.
Secondly, different working roles. The air cooling tower is mainly used to cool the high-temperature compressed air discharged from the air compressor, reduce the air temperature, wash the dust and oil in the air, purify the air and provide qualified air intake for the molecular sieve. The water cooling tower mainly cools the high-temperature return water after the air cooling tower is used, so as to realize recycling of circulating water and save water resources.
Third, the cold sources are different. The air cooling tower relies on the cold water cooled by the water cooling tower to complete heat exchange; The water cooling tower uses the low-temperature dry nitrogen discharged from the air separation rectification tower as the cold source, and uses the evaporation and heat absorption to reduce the water temperature.
Fourth, different process locations. The air cooling tower is located behind the air compressor and in front of the molecular sieve; The water cooling tower belongs to the circulating water cooling system and is independently matched. To sum up, the cooling air of air cooling tower and cooling water of water cooling tower cooperate to ensure stable temperature and economical operation of air separation system.

DEAR Air Separation Solve YourWhat is the difference between air cooling tower and water cooling tower of air separation equipment?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top