How to prevent water ingress accidents in the molecular sieve purification system of air separation equipment?Air separation equipment molecular sieve purification system water inlet accident how to p

How to prevent water ingress accidents in the molecular sieve purification system of air separation equipment?Air separation equipment molecular sieve purification system water inlet accident how to p
Apr 03, 2025
Author: DEAR AST

The molecular sieve purification system is a key part of the air separation equipment, used to adsorb impurities such as water, CO₂ and hydrocarbons. Water intake will lead to molecular sieve failure, equipment corrosion and operational failure.
Preventive measures:
1. Optimize the operation of the pre-cooling system, regularly check the chilled water unit and pump to ensure that the outlet air temperature is ≤15℃. Install high-efficiency air-water separator and set liquid level interlock alarm (automatic drainage when liquid level is too high).
2. Valve and pipeline management, choose switching valves with double sealing structure, and conduct sealing test (such as helium leakage detection) every month. Install on-line dew point meter at the inlet of molecular sieve (the alarm value is set to -40℃). Thoroughly empty the pipeline when shutting down and purge with dry nitrogen gas.
3. Standardize the operation procedure and perform at least 2 hours of low-pressure air purging (flow rate ≥ 0.5m/s) before start-up. Strictly monitor the regeneration temperature curve to ensure that the center temperature of the molecular sieve bed is ≥180℃. 4.
4. Add protective measures to install electric heaters in front of the molecular sieve adsorber (to quickly warm up and remove water in case of emergency). Configure standby adsorber to switch and isolate the faulty unit immediately after water intake.
Molecular sieve purification system water inlet accidents mostly stem from equipment defects or operational negligence, need to be pre-cooling system monitoring, valve sealing check, standardize the operation of the trinity of prevention. Once the water inlet, it should be shut down immediately to avoid the expansion of the accident. Regular maintenance and staff training is the key to guarantee the long cycle operation of the system.

DEAR Air Separation Solve YourHow to prevent water ingress accidents in the molecular sieve purification system of air separation equipment?Air separation equipment molecular sieve purification system water inlet accident how to pYou can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
If the temperature after the expander of the air separation unit is too low, it should find out the cause of the low temperature and take measures to increase the temperature after the expander. If the low temperature of expander is caused by liquid air in front of expander, appropriate measures should be taken to reduce the liquid air level of lower column. If it is caused by other reasons, the more effective method is generally throttling in front of the expander. Throttling will not increase the temperature in front of the expander, but throttling will reduce the pressure in front of the expander, so the pressure difference between the front and the back of the expander will be reduced, the expander will do less work and the temperature will be reduced, so the temperature at the after of the expander can be increased.
2026.06.01
What is the principle of return slop nitrogen removing frozen water and carbon dioxide?
2026.05.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top