What are the impacts of scaling in the cooling system of air separation equipment and what corresponding measures should be taken?

What are the impacts of scaling in the cooling system of air separation equipment and what corresponding measures should be taken?
Dec 26, 2024
Author: DEAR AST

Scaling in the cooling system of air separation equipment can have adverse effects on equipment performance, heat transfer efficiency, and system stability.
The thermal conductivity of scale is much lower than that of commonly used metal materials, so the accumulation of scale in cooling water pipes can lead to deterioration of heat transfer and inability to cool the air to the required temperature. This will directly affect the economic efficiency and normal production of the air separation unit, which may lead to a decrease in gas volume. In the air pre cooling system, scaling may lead to a decrease in the performance of equipment such as air cooling towers, water cooling towers, water pumps, and chiller units. The decrease in heat exchange efficiency of the water-cooled tower will cause an increase in the temperature of the chilled water in the outlet cooling tower, indirectly leading to an increase in the temperature of the air in the outlet cooling tower, which is not conducive to the operation of the molecular sieve adsorber. Scaling may lead to increased system resistance, increased energy consumption, and even equipment failure or shutdown.
Corresponding measures: Improve water quality, control the content of hardness substances and impurities such as sediment in cooling water, thereby reducing the degree of scaling. Professional water treatment equipment can be selected for water quality treatment. Install filters in the cooling water system to filter out most of the particles and impurities such as rust, preventing them from settling inside the unit. Filters can effectively protect the unit and improve equipment stability.
Therefore, it is necessary to take measures such as regular cleaning, improving water quality, installing filters, and preventive measures to reduce scaling and ensure the normal operation of equipment.

DEAR Air Separation Solve YourWhat are the impacts of scaling in the cooling system of air separation equipment and what corresponding measures should be taken?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process. Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area. The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g). Deere air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the w
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top