What are the impacts of scaling in the cooling system of air separation equipment and what corresponding measures should be taken?

What are the impacts of scaling in the cooling system of air separation equipment and what corresponding measures should be taken?
Dec 26, 2024
Author: DEAR AST

Scaling in the cooling system of air separation equipment can have adverse effects on equipment performance, heat transfer efficiency, and system stability.
The thermal conductivity of scale is much lower than that of commonly used metal materials, so the accumulation of scale in cooling water pipes can lead to deterioration of heat transfer and inability to cool the air to the required temperature. This will directly affect the economic efficiency and normal production of the air separation unit, which may lead to a decrease in gas volume. In the air pre cooling system, scaling may lead to a decrease in the performance of equipment such as air cooling towers, water cooling towers, water pumps, and chiller units. The decrease in heat exchange efficiency of the water-cooled tower will cause an increase in the temperature of the chilled water in the outlet cooling tower, indirectly leading to an increase in the temperature of the air in the outlet cooling tower, which is not conducive to the operation of the molecular sieve adsorber. Scaling may lead to increased system resistance, increased energy consumption, and even equipment failure or shutdown.
Corresponding measures: Improve water quality, control the content of hardness substances and impurities such as sediment in cooling water, thereby reducing the degree of scaling. Professional water treatment equipment can be selected for water quality treatment. Install filters in the cooling water system to filter out most of the particles and impurities such as rust, preventing them from settling inside the unit. Filters can effectively protect the unit and improve equipment stability.
Therefore, it is necessary to take measures such as regular cleaning, improving water quality, installing filters, and preventive measures to reduce scaling and ensure the normal operation of equipment.

DEAR Air Separation Solve YourWhat are the impacts of scaling in the cooling system of air separation equipment and what corresponding measures should be taken?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top