How can I tell when the moisture and carbon dioxide content of the air is exceeded out of the molecular sieve purifier and what causes it?

How can I tell when the moisture and carbon dioxide content of the air is exceeded out of the molecular sieve purifier and what causes it?
Sep 03, 2024
Author: DEAR AST

Out of the molecular sieve purifier after the air moisture and carbon dioxide content exceeds the standard judgement, usually the following methods:
1)The indication value of the moisture and carbon dioxide detector meter located after the molecular sieve adsorber rises quickly at the end of the cycle and reaches the alarm value quickly;
2) There is freezing of moisture and carbon dioxide in the main heat exchanger. The temperature difference at the hot end increased significantly, and the air separation unit was not cool enough, requiring an increase in the amount of expansion air. Pay special attention to this situation when the moisture and carbon dioxide detection instruments are out of order.
There may be the following reasons for this situation:
1)The molecular sieve has been used for a long time, and the adsorption performance has decreased;
2)Incomplete regeneration of molecular sieve, or steam regeneration heater leakage, regeneration gas moisture; or molecular sieve adsorption of moisture load is too large, affecting the adsorption of carbon dioxide;
3) For horizontal molecular sieve adsorber, the bed layer is uneven due to airflow pulsation and other reasons, resulting in short-circuit airflow;
4) For vertical molecular sieve adsorber, short-circuiting of airflow is caused by gaps in the adsorption bed.

DEAR Air Separation Solve YourHow can I tell when the moisture and carbon dioxide content of the air is exceeded out of the molecular sieve purifier and what causes it?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The liquid air separation plant system uses the cold energy to produce liquid oxygen, liquid nitrogen and liquid argon in an air separation system, including an air compression pre-cooling system, an air purification system, an air separation system and a nitrogen circulation system for liquid air separation plant cold recovery. the nitrogen circulation system for liquid air separation plant cold recovery is placed in a separate cold box from the main cold box of the air separation system. the l...
2026.08.03
In the process of operation, especially in the start-up and shutdown of the air separation unit, one-way force should be avoided on the instrument. During the start-up of the equipment, close the high pressure and low pressure valves firstly, then open the balance valve, and then slowly open the high pressure (or low pressure) valve, so that the measured medium can enter the positive (negative) pressure chamber of the transmitter. If the liquid is to be measured, the gas in the positive (negative) pressure chamber should be discharged from the upper vent. If the gas is measured, drain the liquid accumulated in the positive (negative) pressure chamber from the lower drain screw hole. After discharging the gas (liquid), close the balance valve, and then open the valve on the other side. When the equipment is shut down, the high pressure (or low pressure) valve should be closed first, then the balance valve should be opened, and then the valve should be closed on the other side. Someti
2026.07.31
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top