How can I tell when the moisture and carbon dioxide content of the air is exceeded out of the molecular sieve purifier and what causes it?

How can I tell when the moisture and carbon dioxide content of the air is exceeded out of the molecular sieve purifier and what causes it?
Sep 03, 2024
Author: DEAR AST

Out of the molecular sieve purifier after the air moisture and carbon dioxide content exceeds the standard judgement, usually the following methods:
1)The indication value of the moisture and carbon dioxide detector meter located after the molecular sieve adsorber rises quickly at the end of the cycle and reaches the alarm value quickly;
2) There is freezing of moisture and carbon dioxide in the main heat exchanger. The temperature difference at the hot end increased significantly, and the air separation unit was not cool enough, requiring an increase in the amount of expansion air. Pay special attention to this situation when the moisture and carbon dioxide detection instruments are out of order.
There may be the following reasons for this situation:
1)The molecular sieve has been used for a long time, and the adsorption performance has decreased;
2)Incomplete regeneration of molecular sieve, or steam regeneration heater leakage, regeneration gas moisture; or molecular sieve adsorption of moisture load is too large, affecting the adsorption of carbon dioxide;
3) For horizontal molecular sieve adsorber, the bed layer is uneven due to airflow pulsation and other reasons, resulting in short-circuit airflow;
4) For vertical molecular sieve adsorber, short-circuiting of airflow is caused by gaps in the adsorption bed.

DEAR Air Separation Solve YourHow can I tell when the moisture and carbon dioxide content of the air is exceeded out of the molecular sieve purifier and what causes it?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
(1) The base of the two supports must be on the same level, ensuring that the 4 mark lines on the outside of the vessel's simplified orientation at both ends are level (2) Horizontal adsorber movable support: after the installation level is adjusted, the first nut on the support is tightened and then backed up one turn, then locked with the second nut (3) After the horizontal adsorber is in place, the level of its internal orifice plate <10mm is tested to confirm the level of the marker bar...
2026.04.14
Why is the ASU cold box the core area for air separation?
2026.04.13
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top