How should the molecular sieve adsorption purification process be operated when the air separation equipment resumes power supply after a power outage?

How should the molecular sieve adsorption purification process be operated when the air separation equipment resumes power supply after a power outage?
Jun 18, 2024
Author: DEAR AST

When the air separation equipment of the molecular sieve adsorption purification process resumes power supply after a power outage, the operation should follow the following steps:
1) Make judgments on the potential impact on mechanical equipment such as air compressors in the event of a sudden power outage. If there is no impact, prepare for the start of the air compressor according to the operating procedures of the air compressor;
2) Check and confirm the opening and closing status of equipment valves for chain shutdown;
3) Check and confirm the alarm interlocking items of the air separation device. Recalibrate and confirm the chain control that fails during power outage;
4) Start the air compressor and air pre cooling system according to regulations;
5) Start the molecular sieve adsorber according to the regulations. Continue to complete the pre shutdown procedure. If the shutdown time is long (more than 24 hours), the molecular sieve adsorber should be recycled for one cycle;
6) Based on the length of downtime, the cold end temperature of the main heat exchanger, and the main cold liquid level, determine the starting steps of the air separation equipment according to regulations.

DEAR Air Separation Solve YourHow should the molecular sieve adsorption purification process be operated when the air separation equipment resumes power supply after a power outage?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
According to the daily water quality analysis and laboratory results, supplement the discharge water and control the dosing amount to make it reach the required data index. When the turbidity is >20mgL, increase the amount of drainage water, increase the flow of side filtration, and supplement clean water. According to the current situation of the circulating water system, try to increase the concentration multiple operation to save water and medicine. If the concentration multiplier is g...
2026.09.04
Before the air cooling columnand water cooling columnare hoisted in place, the anchor hole shall be cleaned, and there shall be no water and debris in the anchor hole.   After the air cooling columnand water cooling columnare hoisted in place, the perpendicularity of the equipment shall be checked. The perpendicularity shall be ≤ 1/1000 and the total length shall not exceed 10mm.   The bottom of the anchor bolt shall not touch the bottom of the reserved anchor hole. Af...
2026.09.03
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top