How can you tell when there is a leak in an air separation plant?

How can you tell when there is a leak in an air separation plant?
Jun 12, 2024
Author: DEAR AST

When a leak is generated in an air separation plant, the cooling capacity is insufficient and the main cooling liquid level keeps falling. In the case of a large gas leak, an increase in pressure in the cold box can be observed. If the cold box is not tight, a large amount of cold gas will come out from the gap. In the case of low temperature liquid leakage, no obvious pressure rise and gas escape can be observed, and the base temperature can often be measured to have dropped significantly.
In order to have a preliminary judgement on the leakage site and leakage before shutdown for maintenance, in order to shorten the downtime. Comprehensive use of the following methods of judgement: (1) the purity of the gas escaping from the cold box. When the nitrogen or liquid nitrogen leakage, cold gas nitrogen volume fraction of up to 80% or more; oxygen or liquid oxygen leakage, the volume fraction of oxygen can be tested to a significant increase. (2) Observe the cold box wall ‘sweat’ or ‘frost’ parts. This time to note that the cryogenic liquid leakage, ‘frost’ part of the partial leakage point below. (3) Observe the regularity of the escaping gas. The main judgement switching type heat exchanger switching channel leakage. If the container is used alternately, the leakage can be further judged by switching the use of the container.
In order to judge the accuracy of the leakage, accumulate experience in actual operation practice, but also be familiar with the structure of the cold box and each container, pipeline, valve space location.

DEAR Air Separation Solve YourHow can you tell when there is a leak in an air separation plant?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
If the temperature after the expander of the air separation unit is too low, it should find out the cause of the low temperature and take measures to increase the temperature after the expander. If the low temperature of expander is caused by liquid air in front of expander, appropriate measures should be taken to reduce the liquid air level of lower column. If it is caused by other reasons, the more effective method is generally throttling in front of the expander. Throttling will not increase the temperature in front of the expander, but throttling will reduce the pressure in front of the expander, so the pressure difference between the front and the back of the expander will be reduced, the expander will do less work and the temperature will be reduced, so the temperature at the after of the expander can be increased.
2026.06.01
What is the principle of return slop nitrogen removing frozen water and carbon dioxide?
2026.05.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top