How can you tell when there is a leak in an air separation plant?

How can you tell when there is a leak in an air separation plant?
Jun 12, 2024
Author: DEAR AST

When a leak is generated in an air separation plant, the cooling capacity is insufficient and the main cooling liquid level keeps falling. In the case of a large gas leak, an increase in pressure in the cold box can be observed. If the cold box is not tight, a large amount of cold gas will come out from the gap. In the case of low temperature liquid leakage, no obvious pressure rise and gas escape can be observed, and the base temperature can often be measured to have dropped significantly.
In order to have a preliminary judgement on the leakage site and leakage before shutdown for maintenance, in order to shorten the downtime. Comprehensive use of the following methods of judgement: (1) the purity of the gas escaping from the cold box. When the nitrogen or liquid nitrogen leakage, cold gas nitrogen volume fraction of up to 80% or more; oxygen or liquid oxygen leakage, the volume fraction of oxygen can be tested to a significant increase. (2) Observe the cold box wall ‘sweat’ or ‘frost’ parts. This time to note that the cryogenic liquid leakage, ‘frost’ part of the partial leakage point below. (3) Observe the regularity of the escaping gas. The main judgement switching type heat exchanger switching channel leakage. If the container is used alternately, the leakage can be further judged by switching the use of the container.
In order to judge the accuracy of the leakage, accumulate experience in actual operation practice, but also be familiar with the structure of the cold box and each container, pipeline, valve space location.

DEAR Air Separation Solve YourHow can you tell when there is a leak in an air separation plant?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In the liquid air separation plant, the cooled refrigerant goes to the air machine through the refrigerant delivery pipeline, and the intercooler cools the compressed air to around 10°C, improving the efficiency of the air compressor and reducing the energy consumption of the air compressor. The air separation unit uses circulating nitrogen to recycle and utilise the CNG cold through a heat exchanger, which in turn liquefies the air to transfer the cold to the liquid air separation plant, an...
2026.03.31
The plant operation cycle between two large heating is related to many factors. From an operational point of view, this mainly depends on when the air passage of the main heat exchanger is blocked. The main reason for the blockage is that the moisture and carbon dioxide content in the air entering the unit exceeds the standard, which accumulates and freezes in the main heat exchanger until it is blocked. The abnormal operation of molecular sieve purification system will shorten the operation cycle of the unit. It is mainly caused by the following reasons: 1. The molecular sieve adsorption bed is short circuited. In the process of operation, due to the unstable gas velocity control or switching, the pressure difference between the two tanks is too large, which will affect the bed layer, make the molecular sieve bed uneven and make the bed layer short circuit. In serious cases, the dust screen of the adsorber will break and the molecular sieve powder will enter the heat exchanger c
2026.03.30
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top