How can you tell when there is a leak in an air separation plant?

How can you tell when there is a leak in an air separation plant?
Jun 12, 2024
Author: DEAR AST

When a leak is generated in an air separation plant, the cooling capacity is insufficient and the main cooling liquid level keeps falling. In the case of a large gas leak, an increase in pressure in the cold box can be observed. If the cold box is not tight, a large amount of cold gas will come out from the gap. In the case of low temperature liquid leakage, no obvious pressure rise and gas escape can be observed, and the base temperature can often be measured to have dropped significantly.
In order to have a preliminary judgement on the leakage site and leakage before shutdown for maintenance, in order to shorten the downtime. Comprehensive use of the following methods of judgement: (1) the purity of the gas escaping from the cold box. When the nitrogen or liquid nitrogen leakage, cold gas nitrogen volume fraction of up to 80% or more; oxygen or liquid oxygen leakage, the volume fraction of oxygen can be tested to a significant increase. (2) Observe the cold box wall ‘sweat’ or ‘frost’ parts. This time to note that the cryogenic liquid leakage, ‘frost’ part of the partial leakage point below. (3) Observe the regularity of the escaping gas. The main judgement switching type heat exchanger switching channel leakage. If the container is used alternately, the leakage can be further judged by switching the use of the container.
In order to judge the accuracy of the leakage, accumulate experience in actual operation practice, but also be familiar with the structure of the cold box and each container, pipeline, valve space location.

DEAR Air Separation Solve YourHow can you tell when there is a leak in an air separation plant?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In the operation of the air separation unit, the superheat of the expanded air sent to the upper column is a key parameter affecting the stability of distillation conditions and product purity. The fluctuation of superheat will directly change the gas-liquid load and mass transfer efficiency of the upper column, and then affect the distillation effect and energy consumption of the unit. If the superheat of the expanded air is too high, the gas entering the upper tower will carry a large amount of excess heat, which will significantly increase the gas phase temperature in the tower and aggravate the consumption of cooling capacity in the tower. This will lead to the decrease of reflux ratio in the distillation section of the upper column, insufficient gas-liquid two-phase contact, and poor mass transfer and heat transfer efficiency. At the same time, the increase of superheated gas will raise the rising gas flow in the tower and destroy the balance of distillation conditions, resulting
2026.10.27
DEAR air separation adopts the "software and hardware integration" scheme to implement the energy-saving transformation of air separation. Under normal conditions, the transformation can reduce the power consumption by about 15%. The cooperation supports the EMC (energy management contract) mode. The customer does not need to invest in advance, and the two sides share the saved electricity revenue.
2026.10.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top