How can you tell when there is a leak in an air separation plant?

How can you tell when there is a leak in an air separation plant?
Jun 12, 2024
Author: DEAR AST

When a leak is generated in an air separation plant, the cooling capacity is insufficient and the main cooling liquid level keeps falling. In the case of a large gas leak, an increase in pressure in the cold box can be observed. If the cold box is not tight, a large amount of cold gas will come out from the gap. In the case of low temperature liquid leakage, no obvious pressure rise and gas escape can be observed, and the base temperature can often be measured to have dropped significantly.
In order to have a preliminary judgement on the leakage site and leakage before shutdown for maintenance, in order to shorten the downtime. Comprehensive use of the following methods of judgement: (1) the purity of the gas escaping from the cold box. When the nitrogen or liquid nitrogen leakage, cold gas nitrogen volume fraction of up to 80% or more; oxygen or liquid oxygen leakage, the volume fraction of oxygen can be tested to a significant increase. (2) Observe the cold box wall ‘sweat’ or ‘frost’ parts. This time to note that the cryogenic liquid leakage, ‘frost’ part of the partial leakage point below. (3) Observe the regularity of the escaping gas. The main judgement switching type heat exchanger switching channel leakage. If the container is used alternately, the leakage can be further judged by switching the use of the container.
In order to judge the accuracy of the leakage, accumulate experience in actual operation practice, but also be familiar with the structure of the cold box and each container, pipeline, valve space location.

DEAR Air Separation Solve YourHow can you tell when there is a leak in an air separation plant?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What are the requirements for the design of piping in the cold box of liquid air separation plant? The design of piping in the cold box ofiquid air separation plant is complex and troublesome, and each pipeline has its own process requirements. As one of the most complex components in the cold box of air separation equipment, low temperature piping is the key to ensure the stable and safe operation of small air separation unit. A set of air separation equipment in the cold / hot end of the plat...
2025.05.15
1. Before hoisting, check and confirm whether the crane body, crane legs, lifting rigging and wire rope meet the safety requirements and hoisting conditions. 2. The hanging points of hoisting facilities shall be confirmed to prevent deviation and inclination; steel wire rope or sling shall be used for protection of edges and corners; sling and U-ring shall be used for lifting objects. 3. The commander shall use inter-phone for command, and special personnel shall be assigned for command, and the personnel shall stand at the position where the lifting object can be fully observed; warning isolation shall be set up in the hoisting area, and no one shall stand under the lifting object. 4. For large-scale hoisting, the hoisting safety scheme shall be formulated in combination with the company's special operation system.
2025.05.14
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top