What is the reason for the temperature drop in the expansion of an air separation plant expander being greater than the throttling temperature drop effect?

What is the reason for the temperature drop in the expansion of an air separation plant expander being greater than the throttling temperature drop effect?
Mar 13, 2024
Author: DEAR AST

Air separation equipment in the expander expansion and throttling temperature drop comparison, air from 0.6MPa throttling to 0.1MPa temperature drop is only 1 ℃ or so, and through the expander expansion, the theoretical temperature drop of up to 80 ~ 90 ℃, the temperature drop effect is much better than throttling.
The reason is that the throttling process does not output power externally, and the temperature reduction is caused by the increase of molecular potential energy. Gas expansion in the expander, the gas to promote the impeller rotation, or to promote the piston external work, and the expansion process is carried out very quickly, there is no energy input from the outside world, ideally can be regarded as an adiabatic process. According to the law of conservation of energy, the output of the work only by reducing the energy of the gas (enthalpy) to maintain the balance, so that the kinetic energy of the gas molecules in motion is reduced dramatically, reflected in the temperature drops dramatically.
Therefore, the expansion machine expansion, the temperature of the gas is reduced not only because the pressure is reduced, resulting in an increase in the potential energy of the molecules, so that the kinetic energy of the molecular movement caused by the reduction of the more mainly due to the external work caused by the effect of the temperature drop than the throttling of the effect is much larger.

DEAR Air Separation Solve YourWhat is the reason for the temperature drop in the expansion of an air separation plant expander being greater than the throttling temperature drop effect?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
1. Before filling with pearlite, the water accumulated on the foundation surface of air separation unit must be removed, dried with hot air, and all manholes shall be closed. 2. When filling pearlite, all containers and pipes in the cold box should be inflated and kept at 50kPa pressure, then slightly open the valve of each meter pipeline, and all thermometers should be electrified to check whether the thermometer cable is damaged during the filling process. 3. The filled pearlite shall not be mixed with combustibles. 4. When filling with pearlite, coarse mesh or pearlite pouring device should be set at the manhole on the top of the cold box to prevent whole bag pearlite from entering the cold box. 5. After the pearlite is filled, the manhole shall be sealed.
2026.08.18
What is the oxygen extraction rate?
2026.08.17
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top