1) Main functions

Cool the moist air after pressurization of the air compressor and further wash away impurities such as microparticle dust and some water-soluble substances (NH3, SO2, etc.) in the air. The air cooled by the air cooling tower is approximately saturated with humid air. According to the working characteristics of the purification system, the lower the temperature of the humid air exiting the air cooling tower, the lower the water content, which is more conducive to reducing the adsorption load of the purification system.

2) Working principle and process

The air cooling tower is divided into two sections, the lower section is cooled by circulating water, and the upper section is cooled by chilled water. The cooling water and chilled water are directly used to exchange heat with moist air on the loose packing to reduce the temperature of the humid air. Cooling water is introduced from the lower part of the air cooling tower, while chilled water is introduced from the upper part of the air cooling tower. The cooling water comes from the factory's cooling water supply network pool, which is pressurized by the cooling water pump and introduced. After heat exchange, it is collected at the bottom of the air cooling tower and returned to the cooling water return network. Frozen water comes from a circulating water tank, which comes into contact with dry sewage nitrogen in the water cooling tower. It uses the latent heat of water vaporization to achieve cooling, and then further lowers the temperature through an ammonia freezer. It is then pressurized and introduced into the chilled water pump. A water collector is installed at the top of the air cooling tower to separate the free water carried in the air.

DEAR Air Separation Solve YourWhat are the main functions, working principles, and processes of the pre cooling system for air separation equipment?You can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The plant operation cycle between two large heating is related to many factors. From an operational point of view, this mainly depends on when the air passage of the main heat exchanger is blocked. The main reason for the blockage is that the moisture and carbon dioxide content in the air entering the unit exceeds the standard, which accumulates and freezes in the main heat exchanger until it is blocked. The abnormal operation of molecular sieve purification system will shorten the operation cycle of the unit. It is mainly caused by the following reasons: 1. The molecular sieve adsorption bed is short circuited. In the process of operation, due to the unstable gas velocity control or switching, the pressure difference between the two tanks is too large, which will affect the bed layer, make the molecular sieve bed uneven and make the bed layer short circuit. In serious cases, the dust screen of the adsorber will break and the molecular sieve powder will enter the heat exchanger c
2026.03.30
What is the oxygen internal compression process
2026.03.27
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top