How to determine if there is a leakage inside the air separation equipment?

How to determine if there is a leakage inside the air separation equipment?
Jan 24, 2024
Author: DEAR AST

When there is a leak in the cold box of the air separation tower, the cooling capacity to maintain normal production appears insufficient. Therefore, the main sign is the continuous decrease of the main cooling liquid level.

If a large amount of gas leaks, an increase in pressure inside the cold box can be observed. If the cold box is not tight, a large amount of cold air will emerge from the gap. However, when low-temperature liquid leaks, there is no obvious increase in pressure or gas escape, and a significant decrease in the base temperature can often be measured.

In order to make a preliminary judgment on the leakage location and material before shutdown for maintenance, and to shorten the downtime, the following methods are comprehensively used:

(1) It tests the purity of the gas escaping from the cold box. When nitrogen or liquid nitrogen leaks, the purity of nitrogen reaches over 80%, and when oxygen or liquid oxygen leaks, the purity of oxygen significantly increases.

(2) Observe the "sweating" or "frosting" area on the cold box wall. At this time, pay attention to the "frosting" area located below the leakage point when low-temperature liquid leaks.

(3) Observe if there is any regularity in the escape of gas.

DEAR air separation equipment manufacturing achieves safe operation and maintenance, stable and efficient operation.

DEAR Air Separation Solve YourHow to determine if there is a leakage inside the air separation equipment?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
How to maintain the operation and maintenance intercooler box of air separation equipment?
2026.01.26
The amount of liquid nitrogen removed from the lower column of the air separation unit will affect the purity of the liquid nitrogen in the lower column and the oxygen enriched liquid air at the bottom of the column. When the liquid nitrogen removal amount of the lower column increases, the reflux liquid participating in the heat and mass exchange of the lower column will be reduced, the temperature rise of the rising steam on the column plate will be correspondingly reduced, the condensation of the rising steam will not be sufficient, the oxygen component will be condensed less, the purity of nitrogen at the column top will be reduced, and the purity of liquid nitrogen will be naturally reduced. At the same time, the temperature rise of the downflow liquid will increase, the liquid evaporation will be more sufficient, more nitrogen components will be evaporated to the top of the column, and the purity of the liquid air at the bottom of the column will be improved accordingly.
2026.01.23
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top