当前位置: Home / Faq / Large air separation FAQ /

How to adjust when the argon fraction of the air separation equipment changes

How to adjust when the argon fraction of the air separation equipment changes
Nov 21, 2023
Author: DEAR AST

The air separation equipment with an argon tower requires a particularly stable operating condition, as the distribution of argon in the upper tower is not fixed and unchanging. When the purity of oxygen and nitrogen changes, i.e. there is a slight change in operating conditions, the distribution of argon in the tower also changes accordingly. However, the position of the argon fraction extraction port is fixed, so the composition of the argon fraction extraction port will also change.

The change in argon fraction directly affects the argon fraction entering the crude argon tower. When the condensing capacity of the coarse argon tower condenser is constant, the higher the oxygen content in the argon fraction, the more argon fraction enters the coarse argon tower. On the contrary, there are fewer. At the same time, the liquid to gas ratio of the upper tower also changes accordingly. In this way, the working conditions of the crude argon tower are unstable and even unable to work.

How to adjust when the argon fraction changes? When the argon fraction does not meet the requirements and the nitrogen content is too high, the oxygen supply valve can be turned down and the nitrogen discharge valve can be turned up. At this point, the rich argon region in the distillation section rises, and the nitrogen content in the argon fraction decreases; At the same time, the oxygen content increases and the argon content also decreases. When the argon content in the fraction is too low, turning down the liquid nitrogen control valve and improving the nitrogen removal purity can increase the argon content in the fraction. During operation, special attention should be paid to the lifting and lowering of the liquid oxygen surface. The adjustment of oxygen and nitrogen production, as well as the adjustment of air volume, should be carried out slowly and in a timely and appropriate manner, striving for the stability of the liquid oxygen level.

DEAR Air Separation Solve YourHow to adjust when the argon fraction of the air separation equipment changesYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
How many adsorbers are there in the purification system of air separation equipment?
2024.04.30
At the installation site of the air separation plant, we may see a variety of operation methods. We may be a little surprised when we first see it. We may get used to it if we see it many times. However, many accidents are caused by our negligence and carelessness. The following are some common sense of safe construction, hoping to be helpful to everyone: 1. Workers must wear safety helmets correctly when entering the construction site, because the construction site is often chaotic. Some equipment installation site, several construction teams are constructing at the same time, it is impossible to completely guarantee that there is no falling objects. 2. Use personal protective equipment correctly, and seriously implement safety protection measures. Safety belts must be fastened when constructing on high places, cliffs and steep slopes without protective facilities. 3. It is forbidden to climb the scaffold, safety protection facilities, etc. It is strictly prohibited to take the ele...
2024.04.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top