The main factors affecting oxygen production are:

1. Insufficient processing air volume. The reasons for insufficient air volume include: high ambient temperature; Atmospheric pressure is too low; The air intake filter is blocked; Low voltage or reduced grid frequency, resulting in a decrease in speed; The cooling effect of the intercooler is not good;

Internal leakage between stages; Leakage of valves and pipelines, leakage of automatic valves or switching valves; For the molecular sieve purification process, it may be due to the leakage of the switching butterfly valve.

2. The average purity of nitrogen is too low. The reasons are: the efficiency of the distillation tray is reduced; Excessive cold loss causes excessive expansion air volume; The purity of liquid nitrogen is too low, and the amount of liquid nitrogen is too large; The amount of liquid nitrogen is too small; Leakage of liquid air or liquid nitrogen subcooler; Excessive removal of contaminated nitrogen (or fractions); The opening of the liquid air and liquid nitrogen control valves is improper, and the working conditions of the lower tower are not adjusted properly.

3. Poor heat exchange of the main cooling system. Insufficient heat exchange surface of the main cooling system, or a large amount of non condensing gas on the nitrogen side, affects the heat transfer of the main cooling system and reduces the evaporation of liquid oxygen.

4. Equipment resistance increases. Due to blockage of the tray, liquid air adsorber, or subcooler, the opening of the liquid air and liquid nitrogen throttle valves is too small or blocked, which will cause an increase in the pressure of the lower tower and a decrease in the amount of air entering the tower. When the switching heat exchanger freezes, it will also cause an increase in system resistance and automatically reduce the amount of air entering the tower.

5. There is a leak in the oxygen pipeline and container.

DEAR Air Separation Industry Co., Ltd. launched the intelligent workshop renovation project for the Deer Air Separation Nonferrous Metal Air Fractionation Tower in April 2019. After six months of production process sorting and optimization design, the intelligent transformation plan was officially determined in November 2019. Through intelligent transformation, Deer Air Separation can achieve mixed production of three types of products: distillation tower pipes, tower bodies, and shaped parts, greatly increasing production capacity, saving labor and time costs. The original production line covering an area of 6000 square meters is optimized and assembled into an intelligent mixed production line covering only 3000 square meters. This transformation can be said to have pioneered intelligent manufacturing in the same industry in China.

DEAR Air Separation Solve YourWhat are the reasons why the oxygen production of air separation equipment cannot meet the targetYou can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top