Influencing factors of cooling effect of nitrogen water tower precooler

Influencing factors of cooling effect of nitrogen water tower precooler
Jun 20, 2025
Author: DEAR AST

The nitrogen water precooler belongs to a mixed heat exchanger. The air directly contacts with the dirty nitrogen in reverse flow. Due to the unsaturation of the dirty nitrogen, a large amount of water evaporates into the dirty nitrogen. The heat taken away is the water temperature decreases. The cooling effect of the precooler of the nitrogen water tower is affected by the spray water volume, the diameter of the sieve plate, the number of plates or the selection of the packing. The most important factor for cooling effect during operation is the ratio of spraying water and air volume, but too low temperature may cause the danger of icing, so the spraying volume of water during operation is generally 0.00055~0.0014m ³/ m ³ A, which can not only achieve the required cooling effect but also prevent icing.

 

DEAR Air Separation Design and Research Institute implements customized design services for each contract requirement and actual situation of each user, and carries out targeted design for the project. It is the basis for the optimization parameters to meet the requirements of optimized rated working conditions, and at the same time, it is the maximum scope for users to make rational use of the site in the space with the site. At the same time, safety should be taken into account to reduce costs for users, which not only ensures the safe operation of the device, but also saves costs for users, demonstrating the excellent quality of Deere fine air separation products everywhere.

DEAR Air Separation Solve YourInfluencing factors of cooling effect of nitrogen water tower precoolerYou can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In the process of operation, especially in the start-up and shutdown of the air separation unit, one-way force should be avoided on the instrument. During the start-up of the equipment, close the high pressure and low pressure valves firstly, then open the balance valve, and then slowly open the high pressure (or low pressure) valve, so that the measured medium can enter the positive (negative) pressure chamber of the transmitter. If the liquid is to be measured, the gas in the positive (negative) pressure chamber should be discharged from the upper vent. If the gas is measured, drain the liquid accumulated in the positive (negative) pressure chamber from the lower drain screw hole. After discharging the gas (liquid), close the balance valve, and then open the valve on the other side. When the equipment is shut down, the high pressure (or low pressure) valve should be closed first, then the balance valve should be opened, and then the valve should be closed on the other side. Someti
2026.07.31
What are the reasons why the oxygen production of air separation equipment cannot meet the target
2026.07.30
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top