What are the requirements for the management of molecular sieve purification system of air separation equipment

What are the requirements for the management of molecular sieve purification system of air separation equipment
Feb 04, 2024
Author: DEAR AST

One important aspect of the management of molecular sieve purification system is the management of "switching device".

The Molecular Sieve Purifier needs to be inspected once a week to check whether the specified temperature is reached during regeneration and cooling, and whether the switching time meets the requirements. If there is any abnormality, it should be adjusted in time. After the purifier is used for one to two years, the particle breakage of molecular sieve and activated alumina shall be measured. If necessary, all the particles shall be taken out and screened to remove the powder and particles. When sieving, be sure to carefully blow and sift to completely remove the particles and powder deposited on it. Molecular sieves and activated alumina should be added or replaced as required. When adding or replacing, molecular sieves and activated alumina from the original supplier should be selected, and the height of the adsorption layer should be ensured to reach the specified thickness.

In addition to providing domestic and foreign customers with high-quality complete sets of air separation equipment, DEAR air separation also provides customers with air separation equipment maintenance for a long time. The operation requirements of each system have relevant technical documents.

DEAR Air Separation Solve YourWhat are the requirements for the management of molecular sieve purification system of air separation equipmentYou can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Screw compressor is a positive displacement compressor from the mechanical type, which is composed of the driving rotor and driven rotor, the main body and a pair of synchronous gears. Therefore, the common faults of screw compressor are as follows: 1. The bearing is burnt out. Because of the foreign matter in the oil system, the oil pressure and the quality of the oil are reduced, resulting in the bearing burning out. The main treatment methods are: check the oil supply system; clean the oil filter and the cooling pipe of the oil cooler; check and adjust the oil pressure regulating valve; test the oil quality, and replace the oil when it is not good; check and deal with the oil leakage points. 2. The rotor is burnt out. When foreign matters enter into the compressed medium system, the temperature of the rotor rises, the temperature of the cooling oil of the rotor increases due to the high temperature of the inhaled medium, and the compression ratio increases, which may cause the
2026.03.20
Why only cryogenic air separation equipment can be selected for large industrial gas?
2026.03.19
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top