当前位置: Home / Faq / Large air separation FAQ /

Why should nitrogen and water precooler be set in the air separation plant?

Why should nitrogen and water precooler be set in the air separation plant?
Feb 05, 2024
Author: DEAR AST
Question Reply

Full low voltageAir separation equipmentNitrogen water precooler is generally set. It mainly uses the unsaturation of the water in the nitrogen to make part of the water evaporate. When the water evaporates, it absorbs the latent heat of vaporization to lower the cooling water temperature, and then uses it to cool the processed air to lower the air temperature entering the tower. Therefore, it includesAir cooling towerAndWater cooling tower.
The fundamental purpose of setting nitrogen-water precooler is to reduce the temperature of air entering the air separation tower and avoid the sharp fluctuation of the temperature entering the tower. Because the air temperature in the tower directly affects the working condition of switching heat exchanger and distillation column and the economy of the whole air separation plant. When designing, the temperature of air entering the tower is generally set at 30℃. When the inlet temperature of the tower is higher than the design index during operation, the throttling refrigerating capacity of the compressed air will be reduced, and the temperature difference at the hot end of the switching heat exchanger and the heat load will be increased, which will lead to the increase of cold loss and energy consumption.
For example, if sewage nitrogen reheat is insufficient, if it increases by 1℃, the energy consumption of the air separation plant will increase by about 2%. Reducing the air temperature into the tower can not only improve the economy of the air separation plant, but also reduce the saturated moisture content in the air. For example, when the absolute pressure of air is 0.6MPa and the air temperature drops from 40℃ to 30℃, the saturated moisture content in every 1kg air will decrease by about 40%. This greatly reduces the burden of self-cleaning of water in switching heat exchanger, which is beneficial to self-cleaning. Therefore, the nitrogen water precooler should be well managed and used to reduce the temperature of air entering the tower as much as possible.
Secondly, in the air cooling tower (Spray Cooling Tower), air and water are in direct contact, which can not only exchange heat but also be washed, and can remove the dust in the air and dissolve some corrosive impurity gas, for example, the material of the aluminum alloy of the Plate-fin switching heat exchanger can be prevented from being corroded and the service life can be prolonged. Because the air cooling tower has a large volume, it can buffer the processed air,Air compressorIt is not easy to overpress when switching.
For the adsorption purification process of molecular sieve,Molecular sieveThe adsorption capacity is related to temperature. The lower the temperature is, the larger the adsorption capacity is. The working cycle of the adsorber of a certain size can be long, or for a certain adsorption cycle, the volume of the designed adsorber can be small, so it is also required to cool the air to the lowest possible temperature in advance. Fully recycle and use the cooling capacity of nitrogen in the nitrogen water precooler to cool the air.

DEAR Air Separation Solve YourWhy should nitrogen and water precooler be set in the air separation plant?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top