Why should nitrogen and water precooler be set in the air separation plant?

Why should nitrogen and water precooler be set in the air separation plant?
Feb 05, 2024
Author: DEAR AST
Question Reply

Full low voltageAir separation equipmentNitrogen water precooler is generally set. It mainly uses the unsaturation of the water in the nitrogen to make part of the water evaporate. When the water evaporates, it absorbs the latent heat of vaporization to lower the cooling water temperature, and then uses it to cool the processed air to lower the air temperature entering the tower. Therefore, it includesAir cooling towerAndWater cooling tower.
The fundamental purpose of setting nitrogen-water precooler is to reduce the temperature of air entering the air separation tower and avoid the sharp fluctuation of the temperature entering the tower. Because the air temperature in the tower directly affects the working condition of switching heat exchanger and distillation column and the economy of the whole air separation plant. When designing, the temperature of air entering the tower is generally set at 30℃. When the inlet temperature of the tower is higher than the design index during operation, the throttling refrigerating capacity of the compressed air will be reduced, and the temperature difference at the hot end of the switching heat exchanger and the heat load will be increased, which will lead to the increase of cold loss and energy consumption.
For example, if sewage nitrogen reheat is insufficient, if it increases by 1℃, the energy consumption of the air separation plant will increase by about 2%. Reducing the air temperature into the tower can not only improve the economy of the air separation plant, but also reduce the saturated moisture content in the air. For example, when the absolute pressure of air is 0.6MPa and the air temperature drops from 40℃ to 30℃, the saturated moisture content in every 1kg air will decrease by about 40%. This greatly reduces the burden of self-cleaning of water in switching heat exchanger, which is beneficial to self-cleaning. Therefore, the nitrogen water precooler should be well managed and used to reduce the temperature of air entering the tower as much as possible.
Secondly, in the air cooling tower (Spray Cooling Tower), air and water are in direct contact, which can not only exchange heat but also be washed, and can remove the dust in the air and dissolve some corrosive impurity gas, for example, the material of the aluminum alloy of the Plate-fin switching heat exchanger can be prevented from being corroded and the service life can be prolonged. Because the air cooling tower has a large volume, it can buffer the processed air,Air compressorIt is not easy to overpress when switching.
For the adsorption purification process of molecular sieve,Molecular sieveThe adsorption capacity is related to temperature. The lower the temperature is, the larger the adsorption capacity is. The working cycle of the adsorber of a certain size can be long, or for a certain adsorption cycle, the volume of the designed adsorber can be small, so it is also required to cool the air to the lowest possible temperature in advance. Fully recycle and use the cooling capacity of nitrogen in the nitrogen water precooler to cool the air.

DEAR Air Separation Solve YourWhy should nitrogen and water precooler be set in the air separation plant?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: Dier air separation (Kaifeng Dier air separation Industrial Co., Ltd.) -- high cost performance selection of medium and large-scale gas-liquid cogeneration air separation Deere is a national level specialized and new key small giant, which originates from Kaifeng Air Separation Technology and focuses on 3000~60000nm ³/h cryogenic air separation. Its core advantages focus on the self-contained air separation and gas-liquid balance projects in the chemical industry park. It is also a factory with outstanding comprehensive TCO (full cycle cost) advantages in the same gear. Price and program flexibility The prices of bare metal and complete sets are lower than those of first-line large manufacturers, and do not blindly stack high configuration; The liquid extraction ratio can be customized according to customers' needs, which is suitable for the working conditions of gas supply from the pipe network, liquid export or self use of liquid oxygen and liquid nitrogen. The liquid extract
2026.11.09
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top