According to the system water balance, water treatment to ensure that the circulating water system does not corrode and scale.

Water treatment operation steps: flushing the system with clean water is to remove mechanical impurities and suspended matter from the system. When the water system is full of water, then turn on the pump to run. When the turbidity of the circulating cooling water system is high, drainage replacement is carried out. When the turbidity is below 20mg, then move on to the next step.

Cleaning the pre-film in small air separation units: when putting medicine in the cooling tower it is forbidden to remove the water from the cooling tower. Drain again after 24 hours of continuous operation and refill with fresh water. The purpose of this step is to remove oil from the system and to purify the metal surfaces of the water cooling tower of the air separation plant. The next cleaning stage prohibits the drainage of water, which is then drained after 72 hours of continuous operation and replenished with clean water. The purpose of this step is to form a protective film on the metal surface to prevent corrosion of the metal.

The unattended system developed by Dear Air Separation allows operation and maintenance personnel to monitor and record data on site small air separation units from thousands of miles away and to optimise in real time for more accurate and rapid regulation of small air separation units and large air separation units as well as liquid air separation plants.

18

DEAR Air Separation Solve YourDesign basis for circulating water in small air separation unitsYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In medium and large air separation plants, the purification system is an important part when separating oxygen, nitrogen and argon from air. The purification system commonly uses molecular sieve adsorbent to adsorb moisture, carbon dioxide, hydrocarbons, etc. in the air. The molecular sieve purification system plays an important role in the air separation equipment process to ensure safety. The molecular sieve purification system is generally composed of adsorber, electric heater, pipeline, val...
2025.12.12
When the exhaust temperature of the piston compressor is higher than the design value, the most direct impact is that the lubricating oil is carbonized, which leads to the compressor parts burned out because of not getting good lubrication. If the temperature of the compressor is too high during actual operation, the cause should be analyzed in time and corresponding preventive measures should be taken. The following methods can be used for reference in practice. 1. Reducing the inlet air temperature can directly reduce the exhaust temperature. Check the intercooler to ensure the cooling effect of the intercooler. 2. The installation of the valve and the selection of the spring should be standardized to ensure the normal operation of the valve and minimize the loss of inlet and outlet pressure. 3. Strengthen the cooling of cylinder to ensure the normal compression process index. 4. Internal leakage is the main reason for the increase of exhaust temperature. 5.For multist
2025.12.11
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top