Installation of the air pre-cooling system in small air separation unit

Installation of the air pre-cooling system in small air separation unit
Mar 16, 2022
Author: DEAR AST

Installation of the air pre-cooling system in small air separation unit

(1) Air cooling tower is a pressure vessel, the site is strictly prohibited on the tower body fire.

(2) installation requirements: verticality <1/1000, the full length of the range shall not exceed 10mm.

(3) loading material before, clear the tower debris and check the tower pieces of fasteners, confirm no loose, off.

(4) bare cold before, air-cooled tower, water-cooled tower at the top of the screen mist trap again check, confirm no gap, no loose.

(5) filler into the tower before, need to check the filler specifications, apparent quality, strength, quantity, etc. to confirm the correct. If the filler can not be filled immediately, need to be stored in the warehouse, should not be long-term open-air placement.

(6) filler installation: filler shall not be mixed, shall not contact grease. Can not be directly from the top of the tower directly into, should be from different heights of the hole for layering filling.

(7) test pressure: after installation, to work pressure on the system for gas tightness test, maintain pressure time shall not be less than 2 hours, shall not leak.

Dear Air Separation manufactures full set of small air separation units and large air separation units including air pre-cooling systems.

山东传洋集团20000

 

DEAR Air Separation Solve YourInstallation of the air pre-cooling system in small air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
According to the daily water quality analysis and laboratory results, supplement the discharge water and control the dosing amount to make it reach the required data index. When the turbidity is >20mgL, increase the amount of drainage water, increase the flow of side filtration, and supplement clean water. According to the current situation of the circulating water system, try to increase the concentration multiple operation to save water and medicine. If the concentration multiplier is g...
2026.09.04
Before the air cooling columnand water cooling columnare hoisted in place, the anchor hole shall be cleaned, and there shall be no water and debris in the anchor hole.   After the air cooling columnand water cooling columnare hoisted in place, the perpendicularity of the equipment shall be checked. The perpendicularity shall be ≤ 1/1000 and the total length shall not exceed 10mm.   The bottom of the anchor bolt shall not touch the bottom of the reserved anchor hole. Af...
2026.09.03
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top