Installation of the air pre-cooling system in small air separation unit

Installation of the air pre-cooling system in small air separation unit
Mar 16, 2022
Author: DEAR AST

Installation of the air pre-cooling system in small air separation unit

(1) Air cooling tower is a pressure vessel, the site is strictly prohibited on the tower body fire.

(2) installation requirements: verticality <1/1000, the full length of the range shall not exceed 10mm.

(3) loading material before, clear the tower debris and check the tower pieces of fasteners, confirm no loose, off.

(4) bare cold before, air-cooled tower, water-cooled tower at the top of the screen mist trap again check, confirm no gap, no loose.

(5) filler into the tower before, need to check the filler specifications, apparent quality, strength, quantity, etc. to confirm the correct. If the filler can not be filled immediately, need to be stored in the warehouse, should not be long-term open-air placement.

(6) filler installation: filler shall not be mixed, shall not contact grease. Can not be directly from the top of the tower directly into, should be from different heights of the hole for layering filling.

(7) test pressure: after installation, to work pressure on the system for gas tightness test, maintain pressure time shall not be less than 2 hours, shall not leak.

Dear Air Separation manufactures full set of small air separation units and large air separation units including air pre-cooling systems.

山东传洋集团20000

 

DEAR Air Separation Solve YourInstallation of the air pre-cooling system in small air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What are the causes of icing on the outside of the incubator of air separation unit?
2026.07.16
When the amount of treated air increases, the rising steam in the distillation column will increase, and the amount of liquid to be condensed in the main cooler will increase accordingly, so it has no effect on the reflux ratio in the column. The purity of oxygen and nitrogen remained unchanged in a certain range with the increase of gas volume, and the output increased proportionally with the increase of gas volume. However, with the increase of the amount of condensate in the main cooler, the heat load of the main cooler increases. When the heat transfer area is insufficient, the temperature difference of the main cooler will inevitably expand, and the pressure of the lower column will increase accordingly. At the same time, with the increase of gas velocity in the column, the amount of downflow liquid increases, and the liquid layer on the tray thickens, which increases the resistance of the tray and the pressure of the upper and lower columns. This will adversely affect the sepa
2026.07.15
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top