当前位置: Home / Faq / Liquefied air separation FAQ /

Fast Variable Load Technology of Liquid Air Separation Plant

Fast Variable Load Technology of Liquid Air Separation Plant
Dec 30, 2025
Author: DEAR AST

A low pressure nitrogen expander is added to the process design. The pressure nitrogen from the pressure tower and high pressure expander is expanded into low pressure nitrogen, which is combined with the nitrogen coming from the low pressure tower and fed into the charge gas compressor. This is specially set up for rapid oxygen load changes. The oxygen product flow rate during normal operation corresponds to the amount of oxygen contained in the amount of air entering the air separation unit. That is, the amount of liquid oxygen pumped from the low pressure tower into the storage tank is the same as the amount of liquid oxygen extracted from the storage tank and pressurized by the liquid oxygen pump to the main heat exchanger of liquid air separation plant.

With this nitrogen cycle rapid load change technology, compared with the conventional air booster internal compression process, it is not only possible to meet a large range of rapid oxygen production changes without bypass or additional compressors, but also to minimize the impact of compressor flow and pressure changes on the distillation column caused by a wide range of variable loads. The working condition in the distillation tower remains basically unchanged when the oxygen output varies from ±20,000Nm3/h at the operating point.

上海宝冶集团有限公司-7500

DEAR Air Separation Solve YourFast Variable Load Technology of Liquid Air Separation PlantYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Liquid air separation plant cold energy utilises air separation equipment, generally large air separation equipment with 2 combined expanders. The price is around 4 million RMB. The expansion air in the air separation plant is no longer required, so for the internal compression process air separation, the inlet air volume of the circulating booster is reduced by about 40% (from 5.A-2A). The energy consumption of the booster is reduced and the investment is reduced. Liquid air separation equipmen...
2026.06.18
1.In the process of preparation and implementation of hoisting construction, the safety and quality assurance system must ensure the normal operation,to ensure that the hoisting project meets the requirements of safety and quality. Before hoisting, safety and quality inspection must be carried out, and it must comply with the code forLifting construction of chemical engineering construction (HG20201-2000) and other regulations and specifications. 2.The crane performance shall meet the requirements of hoisting process, and the alarm and hydraulic system must be reliable. 3.Strictly implement the provisions of the technical documents attached to the crane. 4.The hoisting schedule of auxiliary crane should match that of main crane. 5.The hook deflection angle shall not be greater than 3°. 6.It is forbidden to drag the unitdirectly on the ground with crane. 7.Before unithoisting, trial hoisting shall be carried out. The clear hoisting distance and the foundation change at
2026.06.17
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top