What are the causes of molecular sieve water ingress accidents of liquid air separation plant? 

What are the causes of molecular sieve water ingress accidents of liquid air separation plant? 
Aug 26, 2025
Author: DEAR AST

Causes of molecular sieve into the water accident: when the air-cooled tower level is higher than 3500mm water exceeds the height of the air inlet tube, a large amount of water with the air into the molecular sieve adsorber; when the air-cooled tower resistance rises, higher than 7kPa, the air-cooled tower will form a liquid suspension of liquid air separation plant, resulting in bottom water level fluctuations, air-cooled tower resistance fluctuations, water with the air into the molecular sieve adsorber; molecular sieve switching program disorder, resulting in a sudden air through the Molecular sieve adsorber airproof, air-cooled tower airflow speed accelerated sharply, water with the air into the molecular sieve adsorber; instrument air pressure is reduced, pneumatic valve self-adjustment out of control, resulting in a rise in the water level; cooling water, chilled water flow is too large, so that the air-cooled tower night hanging.

 

After the occurrence in liquid air separation plant, should first deal with the air-cooled tower working conditions, stop the pump water supply, the air-cooled tower level down, and make it return to normal working conditions. At the same time the liquid air separation plant to reduce the production to reduce the amount of molecular sieve load, and through the purifier pressure, resistance, regeneration temperature curve and purifier after the carbon dioxide content to determine the water situation, such as into the water is not large due to immediately take remedial adjustment conditions (such as: increase the heating temperature, increase the heating and cold blowing flow, extend the heating time and switching procedures to switch ahead, etc.). If the water volume is too large, the molecular sieve purifier needs to be activated, when activation, pay attention to the first cold blowing with a large airflow, in the free water blowing net then heating. If the activation operation is unsuccessful, the molecular sieve can only be replaced.

 

Dear Air Separation has standardised design requirements and technical documentation for the production of liquid air separation plant to ensure quality operation.
3

DEAR Air Separation Solve YourWhat are the causes of molecular sieve water ingress accidents of liquid air separation plant? You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top