当前位置: Home / Faq / Liquefied air separation FAQ /

LNG Cold Energy Utilisation Air Separation Unit

LNG Cold Energy Utilisation Air Separation Unit
Sep 01, 2025
Author: DEAR AST

LNG Cold Energy Utilisation Air Separation Plant is a liquid air separation plant for the utilization of LNG cold energy with a high utilization rate of cold energy, energy saving and environmental protection, high efficiency and safety factor.

Liquid air separation plant for LNG cold energy, including air compression pre-cooling system, purification system, air separation system, nitrogen circulation system. The nitrogen circulation system consists of a high pressure heat exchanger to recover the LNG cold, two low temperature circulation nitrogen presses and two gas-liquid separators, which are placed in separate cold boxes. The nitrogen is compressed by two low temperature circulating nitrogen presses and cooled to liquid nitrogen by heat exchange with LNG, which is separated into gas and liquid nitrogen in the gas-liquid separator. The gas nitrogen is returned to the compressor to circulate and compress the refrigeration liquid nitrogen, part of which is sent out as product and part of which is sent to the liquefier to heat exchange with part of the air, which is then liquefied and sent to the lower fractionation tower, where the cold volume of LNG is transferred to the liquid air separation plant . The liquid nitrogen is vaporised and reheated before being circulated.

DearAir manufactures advanced LNG cold energy utilization liquid air separation units.

252058689457107136

DEAR Air Separation Solve YourLNG Cold Energy Utilisation Air Separation UnitYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
It should contact with the front and rear processes when the piston compressor is ready to stop, we should pay attention to the following sequence: first, cut off the gas supply slowly. In order to prevent the outlet pressure from rising after the gas supply is cut off, open the vent valve at the same time. For the oxygen compressor, the vent valve should be opened slowly, because excessive opening may produce static electricity and cause fire. Then, stop the motor. After the motor stops, turn off the circulating oil pump, grease injector motor and cooling water valve. However, there are also exception cases. For example, in case of emergency shutdown, in order to save time and prevent the accident from expanding, the power supply can be cut off immediately to stop the compressor with load.
2026.01.28
Why do gas nitrogen and liquid nitrogen coexist at the top of the distillation tower of an air separation plant
2026.01.27
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top