Centrifugal compressor operation once the phenomenon of wheezing, the unit and the operation of the pipe network has the following characteristics.

(1) the gas medium outlet pressure and inlet flow rate changes significantly, sometimes may also produce gas backflow phenomenon. The gas medium is discharged from the compressor to the inlet, which is a dangerous working condition.

(2) Periodic vibrations in the pipe network, with high amplitude and low frequency, accompanied by a periodic "roar" sound.

(3) The compressor body vibrates strongly, the casing, bearings have strong vibration, and a strong periodic airflow sound, due to strong vibration, bearing lubrication conditions will be damaged, shaft tile will burn, or even shaft is twisted off, the rotor and stator will produce friction, collision, sealing components will be seriously damaged.

Once the compressor enters the wheezing condition, the operator should immediately take adjustment measures to reduce the outlet pressure, so that the compressor in small air separation unit quickly out of the wheezing zone, to achieve stable operation of the compressor.

主图

 

 

DEAR Air Separation Solve YourCharacteristics of centrifugal compressor wheezing phenomenon in small air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
It should contact with the front and rear processes when the piston compressor is ready to stop, we should pay attention to the following sequence: first, cut off the gas supply slowly. In order to prevent the outlet pressure from rising after the gas supply is cut off, open the vent valve at the same time. For the oxygen compressor, the vent valve should be opened slowly, because excessive opening may produce static electricity and cause fire. Then, stop the motor. After the motor stops, turn off the circulating oil pump, grease injector motor and cooling water valve. However, there are also exception cases. For example, in case of emergency shutdown, in order to save time and prevent the accident from expanding, the power supply can be cut off immediately to stop the compressor with load.
2026.01.28
Why do gas nitrogen and liquid nitrogen coexist at the top of the distillation tower of an air separation plant
2026.01.27
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top