Grid frequency or voltage drop

Combined with the compressor machine side voltage meter and electrical system background microcomputer found that during the operation of the compressor grid voltage and frequency are not significantly decreased, the external network power supply system is more stable, so the motor and compressor speed is judged to be a constant value.

 

Increase in suction temperature at any level

When the suction temperature of any level rises, the gas density decreases, which will cause the suction volume to decrease and eventually affect the exhaust volume of the unit.

 

Leaking coolers

If the cooler leaks, the cooling water in the low-pressure cooler enters the air side pass and is further entrained by the airflow into the impeller and diffuser, causing scaling and blockage over time and reducing the air flow. To verify whether there are leaks in the coolers, the condensate discharged from the blow-off valves of the cooler stages is continuously monitored by laboratory tests.

The hardness of the condensate from the first and second section coolers of the air compressor exceeded the standard, which indicated that there was a leak inside the first and second section coolers. The leaking circulating cooling water entrained by the airflow enters the second stage impeller, and the water evaporates rapidly under the high temperature and high pressure working environment, and the precipitated calcium and magnesium plasma precipitates and accumulates on the internal runner surface of the second stage impeller, causing the circulation area to be reduced and the air intake of the air compressor to be reduced.

 

The air compressors developed by Dear Air Separation have reduced carbon emissions and saved customers nearly $10 million in annual operating costs.

低温液化空分装置 (1)

DEAR Air Separation Solve YourLow air compressor efficiency of large air separation unitYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In the liquid air separation plant, the cooled refrigerant goes to the air machine through the refrigerant delivery pipeline, and the intercooler cools the compressed air to around 10°C, improving the efficiency of the air compressor and reducing the energy consumption of the air compressor. The air separation unit uses circulating nitrogen to recycle and utilise the CNG cold through a heat exchanger, which in turn liquefies the air to transfer the cold to the liquid air separation plant, an...
2026.03.31
The plant operation cycle between two large heating is related to many factors. From an operational point of view, this mainly depends on when the air passage of the main heat exchanger is blocked. The main reason for the blockage is that the moisture and carbon dioxide content in the air entering the unit exceeds the standard, which accumulates and freezes in the main heat exchanger until it is blocked. The abnormal operation of molecular sieve purification system will shorten the operation cycle of the unit. It is mainly caused by the following reasons: 1. The molecular sieve adsorption bed is short circuited. In the process of operation, due to the unstable gas velocity control or switching, the pressure difference between the two tanks is too large, which will affect the bed layer, make the molecular sieve bed uneven and make the bed layer short circuit. In serious cases, the dust screen of the adsorber will break and the molecular sieve powder will enter the heat exchanger c
2026.03.30
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top