Low air compressor efficiency of large air separation unit

Low air compressor efficiency of large air separation unit
Mar 07, 2025
Author: DEAR AST

Grid frequency or voltage drop

Combined with the compressor machine side voltage meter and electrical system background microcomputer found that during the operation of the compressor grid voltage and frequency are not significantly decreased, the external network power supply system is more stable, so the motor and compressor speed is judged to be a constant value.

 

Increase in suction temperature at any level

When the suction temperature of any level rises, the gas density decreases, which will cause the suction volume to decrease and eventually affect the exhaust volume of the unit.

 

Leaking coolers

If the cooler leaks, the cooling water in the low-pressure cooler enters the air side pass and is further entrained by the airflow into the impeller and diffuser, causing scaling and blockage over time and reducing the air flow. To verify whether there are leaks in the coolers, the condensate discharged from the blow-off valves of the cooler stages is continuously monitored by laboratory tests.

The hardness of the condensate from the first and second section coolers of the air compressor exceeded the standard, which indicated that there was a leak inside the first and second section coolers. The leaking circulating cooling water entrained by the airflow enters the second stage impeller, and the water evaporates rapidly under the high temperature and high pressure working environment, and the precipitated calcium and magnesium plasma precipitates and accumulates on the internal runner surface of the second stage impeller, causing the circulation area to be reduced and the air intake of the air compressor to be reduced.

 

The air compressors developed by Dear Air Separation have reduced carbon emissions and saved customers nearly $10 million in annual operating costs.

低温液化空分装置 (1)

DEAR Air Separation Solve YourLow air compressor efficiency of large air separation unitYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top