当前位置: Home / Faq / Large air separation FAQ /

Principles of air purification

Principles of air purification
Nov 19, 2021
Author: DEAR AST

In addition to dust, there are also water, carbon dioxide and hydrocarbons in the feed gas, which are removed by molecular sieve purification system. The purpose of removing impurities is as follows:

1. Prevent impurities from blocking and freezing on equipment and pipelines. Affect the normal operation of the device;

2. Prevent the equipment from being corroded;

3. Remove the dangerous explosives that threaten the safe operation of cryogenic equipment. Therefore, gas filtration, precooling and purification equipment is an indispensable part of the air separation unit.

 

DEAR Air Separation has a number of patented technologies, of which two ultra-low discharge pressure energy-saving patents belong to the domestic leading level, which can reduce the energy consumption of biogas purification equipment by 5% - 15%, and save operating costs.

 

The remote intelligent monitoring system independently developed by DEAR Air Separation enables the whole process intelligent management of equipment field and remote monitoring terminal, early detection and early warning of faults, and saves the labor cost of field operators.

 

DEAR Air Separation has invested a lot to build an intelligent production workshop to ensure that the product quality is close to zero defects, improve the accuracy of biogas purification equipment and shorten the scheduled cycle.

1

DEAR Air Separation Solve YourPrinciples of air purificationYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top