Requirements for orifice plate installation

Requirements for orifice plate installation
Jun 17, 2021
Author: DEAR AST

The poor installation quality of orifice flowmeter will affect the reading accuracy of orifice flowmeter. In order to improve the reading accuracy of orifice flowmeter, the following points should be paid attention to in the installation of orifice flowmeter: the installation position of orifice flowmeter should be in the straight pipe section, in the pipe with a distance of ten times the diameter of orifice before and five times the diameter of orifice behind, no protruding plastics, welding marks and dirt are allowed. The installation direction of the orifice plate should not be wrong, and the sharp edge of the inlet should face the flow direction of the fluid; The center of the orifice plate must coincide with the center of the pipe, because that the coefficient K in the flow calculation formula is related to the fluid density and other factors.

DEAR Air Separation Solve YourRequirements for orifice plate installationYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
At the installation site of the air separation plant, we may see a variety of operation methods. We may be a little surprised when we first see it. We may get used to it if we see it many times. However, many accidents are caused by our negligence and carelessness. The following are some common sense of safe construction, hoping to be helpful to everyone: 1. Workers must wear safety helmets correctly when entering the construction site, because the construction site is often chaotic. Some equipment installation site, several construction teams are constructing at the same time, it is impossible to completely guarantee that there is no falling objects. 2. Use personal protective equipment correctly, and seriously implement safety protection measures. Safety belts must be fastened when constructing on high places, cliffs and steep slopes without protective facilities. 3. It is forbidden to climb the scaffold, safety protection facilities, etc. It is strictly prohibited to take the ele...
2024.04.29
What are the signs of excessive carbon dioxide and water in the air after the molecular sieve adsorber of the air separation equipment? What is the reason?
2024.04.28
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top