当前位置: Home / Faq / Liquefied air separation FAQ /

Requirements for orifice plate installation

Requirements for orifice plate installation
Dec 04, 2024
Author: DEAR AST

The poor installation quality of orifice flowmeter will affect the reading accuracy of orifice flowmeter. In order to improve the reading accuracy of orifice flowmeter, the following points should be paid attention to in the installation of orifice flowmeter: the installation position of orifice flowmeter should be in the straight pipe section, in the pipe with a distance of ten times the diameter of orifice before and five times the diameter of orifice behind, no protruding plastics, welding marks and dirt are allowed. The installation direction of the orifice plate should not be wrong, and the sharp edge of the inlet should face the flow direction of the fluid; The center of the orifice plate must coincide with the center of the pipe, because that the coefficient K in the flow calculation formula is related to the fluid density and other factors.

DEAR Air Separation Solve YourRequirements for orifice plate installationYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Why do molecular sieves in small air separation unit use bunk beds? Molecular sieve purifiers are used in both small and large air separation plants to purify the air. carbon dioxide, acetylene, and various hydrocarbons. Some molecular sieves small air separation unit use a double bed because the adsorption capacity of activated alumina is relatively large for air with high water content, but as the water content of the air decreases, the adsorption capacity decreases rapidly. The molecular s...
2026.01.29
It should contact with the front and rear processes when the piston compressor is ready to stop, we should pay attention to the following sequence: first, cut off the gas supply slowly. In order to prevent the outlet pressure from rising after the gas supply is cut off, open the vent valve at the same time. For the oxygen compressor, the vent valve should be opened slowly, because excessive opening may produce static electricity and cause fire. Then, stop the motor. After the motor stops, turn off the circulating oil pump, grease injector motor and cooling water valve. However, there are also exception cases. For example, in case of emergency shutdown, in order to save time and prevent the accident from expanding, the power supply can be cut off immediately to stop the compressor with load.
2026.01.28
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top