What should be paid attention to in molecular sieve purification of air separation unit

What should be paid attention to in molecular sieve purification of air separation unit
Apr 22, 2021
Author: DEAR AST

Molecular sieve purification of air separation unit includes cooling unit stage, liquid accumulation stage and three chamber adjustment stage. In the start-up process, the main focus is to give full play to the refrigeration capacity of the expander, reasonably distribute the cooling capacity and fully cool the unit.

 

Attention should be paid to the following aspects:

 

  1. The molecular sieve used for the first time should be activated and regenerated once to remove the water and carbon dioxide adsorbed during transportation and filling. The activation temperature is generally higher than 200 ℃ and lower than 250 ℃. When the outlet temperature reaches 80 ℃, it can be cold blown. The activation time is not less than two cycles;

 

  1. When the molecular sieve is started, the air supply process should be slow, and the vent valve should be carefully closed to prevent the molecular sieve in the bed from being damaged due to pressure fluctuation;

 

  1. When the two expanders need to be started, the return valve of the booster should be fully opened to reduce the pressure of the first expander, and then the two expanders should be loaded at the same time to prevent the surge of the later booster;

 

  1. Pay attention to the temperature control in the middle of the heat exchanger;

 

  1. Pay attention to the work of air cooling columnto ensure that the air after precooling meets the design requirements.
DEAR Air Separation Solve YourWhat should be paid attention to in molecular sieve purification of air separation unitYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The molecular sieve used in oxygen generators is the zeolite molecular sieve. It is a crystalline silica and aluminate polyhydric compound. Molecular sieves have a uniform pore size and their main function is to sieve molecules. There are three main types of molecular sieves: A, X and Y. The 13X molecular sieve is the only adsorbent currently used in liquid air separation plants. Any molecules that can be adsorbed on 3A, 4A and 5A molecular sieves can be adsorbed by 13X molecular sieves. It is c...
2026.09.30
Pressure test before valve installation 1. In the warranty period, those with the certification and the sealing surface is intact can no longer conduct the strength test alone, but only the air tightness test can be taken before installation. 2. Within the warranty period, it has the certificate, and its sealing surface has defects such as corrosion and damage. After treatment, it must carry out the air tightness test. 3. Outside the warranty period, those with certification and intact sealing surface shall be subject to air tightness test before installation. 4. For valves that need to be degreased and disassembled on site, air tightness test shall be conducted separately before installation. 5. The safety valve shall be sent to the local quality inspection department of the project for verification before the end of installation and commissioning.
2026.09.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top