What should be paid attention to after using molecular sieve to purify air?

What should be paid attention to after using molecular sieve to purify air?
Aug 04, 2023
Author: DEAR AST

1) A little bit more work pressure is needed. The pressure depends on whether to use the original dryer valve or switch to the large diameter valve when switching to the molecular sieve purifier; whether to use the original dryer pipeline or to thicken the pipeline. If the valve is larger and the pipe is thicker, the increase of working pressure is smaller. If the valves and pipes of the original dryer are used, the pressure of the upper column will increase by about 0.01 MPa, and the pressure of the lower column will increase accordingly. Otherwise, the regeneration temperature of Molecular Sieve Purifier will not meet the requirements within the predetermined time.

 

2) The regeneration temperature of molecular sieve purifier must be strictly controlled. The temperature of heated nitrogen from the heating furnace should not be too high or too low, usually controlled at 280-320 ℃. If the temperature is too high, the furnace is prone to failure; if the temperature is too low, the heating regeneration cycle will be extended. When the temperature rises to 110 ° C, the nitrogen is heated out of the purifier to stop heating. After the power supply of the electric furnace is cut off, the temperature of the heated nitrogen from the purifier may also rise to more than 130 ° C.

 

3) When the molecular sieve purifier is switched over, air should be filled from above. Although the molecular sieve is full at the initial loading, there will be a gap in the upper part after vibration. If air is filled from below during the switching process, the molecular sieve will jump up and down, causing friction and crushing.

 

4) The molecular sieve purifier should be switched slowly to avoid the fluctuation of working conditions of fractionator or the powder produced due to the influence of gas flow on molecular sieve. When there is an argon column, the molecular sieve purifier needs to be switched stably.

 

5) When shutting down for a long time, nitrogen should be filled to prevent moisture. During long-term shutdown, it is best to fill the purifier with dry nitrogen to maintain pressure. In order to prevent moist air from invading the molecular sieve, the ability of purifying air will be reduced when the molecular sieve is driven again.

DEAR Air Separation Solve YourWhat should be paid attention to after using molecular sieve to purify air?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Liquid air separation plant cold energy utilises air separation equipment, generally large air separation equipment with 2 combined expanders. The price is around 4 million RMB. The expansion air in the air separation plant is no longer required, so for the internal compression process air separation, the inlet air volume of the circulating booster is reduced by about 40% (from 5.A-2A). The energy consumption of the booster is reduced and the investment is reduced. Liquid air separation equipmen...
2026.06.18
1.In the process of preparation and implementation of hoisting construction, the safety and quality assurance system must ensure the normal operation,to ensure that the hoisting project meets the requirements of safety and quality. Before hoisting, safety and quality inspection must be carried out, and it must comply with the code forLifting construction of chemical engineering construction (HG20201-2000) and other regulations and specifications. 2.The crane performance shall meet the requirements of hoisting process, and the alarm and hydraulic system must be reliable. 3.Strictly implement the provisions of the technical documents attached to the crane. 4.The hoisting schedule of auxiliary crane should match that of main crane. 5.The hook deflection angle shall not be greater than 3°. 6.It is forbidden to drag the unitdirectly on the ground with crane. 7.Before unithoisting, trial hoisting shall be carried out. The clear hoisting distance and the foundation change at
2026.06.17
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top