How the operation of molecular sieve purification system affects the operation cycle of air separation unit

How the operation of molecular sieve purification system affects the operation cycle of air separation unit
Dec 11, 2020
Author: DEAR AST
Question Reply

The plant operation cycle between two large heating is related to many factors. From an operational point of view, this mainly depends on when the air passage of the main heat exchanger is blocked. The main reason for the blockage is that the moisture and carbon dioxide content in the air entering the unit exceeds the standard, which accumulates and freezes in the main heat exchanger until it is blocked.

 

The abnormal operation of molecular sieve purification system will shorten the operation cycle of the unit. It is mainly caused by the following reasons:

 

1.The molecular sieve adsorption bed is short circuited. In the process of operation, due to the unstable gas velocity control or switching, the pressure difference between the two tanks is too large, which will affect the bedlayer, make the molecular sieve bed uneven and make the bed layer short circuit. In serious cases, the dust screen of the adsorber will break and the molecular sieve powder will enter the heat exchanger channel, causing blockage;

 

2.Spray cooling columnwith water. The air velocity passing through the spray cooling columnis too high, which causes the water mist to enter the adsorber, thus greatly increasing the load of the adsorber to remove the water. The moisture and carbon dioxide content in the outlet air exceeds the standard and is taken into the main heat exchanger and frozen, increasing the resistance. If the resistance in the cold part increases, the carbon dioxide freezes. If the resistance of the hot part increases, the moisture freezes. The resistance of the whole heat exchanger increases, and they are frozen or the molecular sieve powder is blocked.

 

3.The chiller works abnormally, which leads to the cold water temperature rising and the air cannot be cooled to normal temperature. On the one hand, the amount of saturated water in the air from the spray columnincreases; on the other hand, the adsorption capacity of the molecular sieve decreases.

 

4.if the spray columnis cut off or the water level is too high, the temperature of the molecular sieve adsorber will increase or cause the water ladenaccident.

DEAR Air Separation Solve YourHow the operation of molecular sieve purification system affects the operation cycle of air separation unitYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In medium and large air separation plants, the purification system is an important part when separating oxygen, nitrogen and argon from air. The purification system commonly uses molecular sieve adsorbent to adsorb moisture, carbon dioxide, hydrocarbons, etc. in the air. The molecular sieve purification system plays an important role in the air separation equipment process to ensure safety. The molecular sieve purification system is generally composed of adsorber, electric heater, pipeline, val...
2025.12.12
When the exhaust temperature of the piston compressor is higher than the design value, the most direct impact is that the lubricating oil is carbonized, which leads to the compressor parts burned out because of not getting good lubrication. If the temperature of the compressor is too high during actual operation, the cause should be analyzed in time and corresponding preventive measures should be taken. The following methods can be used for reference in practice. 1. Reducing the inlet air temperature can directly reduce the exhaust temperature. Check the intercooler to ensure the cooling effect of the intercooler. 2. The installation of the valve and the selection of the spring should be standardized to ensure the normal operation of the valve and minimize the loss of inlet and outlet pressure. 3. Strengthen the cooling of cylinder to ensure the normal compression process index. 4. Internal leakage is the main reason for the increase of exhaust temperature. 5.For multist
2025.12.11
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top