The application of saturation in precooling

The application of saturation in precooling
Oct 30, 2024
Author: DEAR AST
Question Reply

When the air is out of the air compressor, due to the compression, the moisture in the air is in the saturated state. After the water cooling column decreasing the temperature, the water content in the saturated state decreases, and the excess water condenses into the water. The water volume in the air cooling column increases and the water temperature rises. But not only is the temperature of the air reduced, but also the moisture content of the air. In the water cooling column, the crude nitrogen is used to cool the water. After passing through the main heat exchanger from the fractionator, the temperature of the crude nitrogen is close to the normal temperature, but it is very dry. The dry crude nitrogen contacts with the water, and a large amount of water is evaporated into the crude nitrogen by using the unsaturation of the crude nitrogen, which absorbs the heat of the water and reduces the water temperature.

DEAR Air Separation Solve YourThe application of saturation in precoolingYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The molecular sieve used in oxygen generators is the zeolite molecular sieve. It is a crystalline silica and aluminate polyhydric compound. Molecular sieves have a uniform pore size and their main function is to sieve molecules. There are three main types of molecular sieves: A, X and Y. The 13X molecular sieve is the only adsorbent currently used in liquid air separation plants. Any molecules that can be adsorbed on 3A, 4A and 5A molecular sieves can be adsorbed by 13X molecular sieves. It is c...
2026.09.30
Pressure test before valve installation 1. In the warranty period, those with the certification and the sealing surface is intact can no longer conduct the strength test alone, but only the air tightness test can be taken before installation. 2. Within the warranty period, it has the certificate, and its sealing surface has defects such as corrosion and damage. After treatment, it must carry out the air tightness test. 3. Outside the warranty period, those with certification and intact sealing surface shall be subject to air tightness test before installation. 4. For valves that need to be degreased and disassembled on site, air tightness test shall be conducted separately before installation. 5. The safety valve shall be sent to the local quality inspection department of the project for verification before the end of installation and commissioning.
2026.09.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top